{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250N3160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250N3160","canonicalUrl":"https://aoctrl.com/schneider/EZCV250N3160","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250N3160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250N series, EZCV250N3160, molded case circuit breaker, 160 A, 3-pole, TM-D thermal-magnetic trip, 20 kA Icu at 440 V AC, with earth-leakage protection.","salesMarkdown":"The Schneider Electric EZCV250N3160 is a 3-pole molded case circuit breaker from the EasyPact EZCV250N series, rated 160 A at 40 °C with a thermal-magnetic TM-D trip unit. It's built for distribution duty — overload, short-circuit, and earth-leakage protection in one package. The 20 kA Icu at 440 V AC (85 kA at 240 V, 25 kA at 415 V) tells you it can handle moderate fault levels on a 400 V line without cascading upstream. The TM-D trip unit gives you fixed thermal (overload) and magnetic (short-circuit) settings; no adjustment dials, so the breaker is matched to the load at order time. Earth-leakage protection is built in, which saves an external RCCB or ground-fault module in panels where that's required. IP20 finger-safe terminals and IK07 impact resistance mean it's fine inside a locked enclosure but not for washdown zones. Fixed backplate mount with front-front connections — both line and load terminals are accessible from the front, which simplifies busbar routing and panel wiring. Toggle control with positive contact indication gives a clear visual of the contact state. Mechanical durability of 10,000 cycles is typical for a distribution breaker — not for frequent switching duty, but fine for infrequent manual operation or remote shunt-trip use.","metaTitle":"Schneider Electric EZCV250N3160 EasyPact MCCB, 160 A, 3P, 20","metaDescription":"Schneider Electric EZCV250N3160 EasyPact EZCV250N molded case circuit breaker, 160 A, 3-pole, 20 kA Icu at 440 V AC. TM-D trip unit with earth-leakage protection. Active production","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"68 mm","Width":"105 mm","Height":"165 mm","Standards":"EN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Earth-leakage protection Overload protection Short-circuit protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"160 A at 40 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZCV250N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"160 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZCV250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"With","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6e6cb39f1e7d80903e7a9a3fdc0822f0.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZCV250N3160/circuit-breaker-easypact-ezcv250n-tmd-160-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZCV250N3160/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for EZCV250N3160?","answer":"Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is the closest alternative to EZCV250N3160 in the EasyPact family?","answer":"The closest peer is the EZCV250N with a different trip rating or without earth-leakage protection. The EZCV250N3160 is distinguished by its 160 A TM-D trip and integrated earth-leakage module — if you don't need ground-fault protection, a standard EZCV250N without the 'E' suffix saves cost."},{"question":"What compliance documentation does Schneider provide for EZCV250N3160?","answer":"The breaker is certified to EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It carries IP20 and IK07 ratings. Isolation suitability is confirmed per IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250N3160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250N3160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}