{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250N3225","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250N3225","canonicalUrl":"https://aoctrl.com/schneider/EZCV250N3225","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250N3225","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250N, molded case circuit breaker, 3P, 225 A at 40 °C, TM-D thermal-magnetic trip unit, 20 kA Icu at 440 V AC, earth-leakage protection, IP20, backplate mount.","salesMarkdown":"It combines overload, short-circuit, and earth-leakage protection in one package — meaning a single device covers the branch circuit protection and ground-fault detection, saving a panel row compared to a breaker plus separate GFCI block. Breaking capacity is 20 kA Icu at 440 V AC (50/60 Hz) per IEC 60947-2, with higher ratings at lower voltages: 25 kA at 380–415 V and 85 kA at 220–240 V. Mounts fixed to a backplate (not DIN rail), with front-front connections — both line and load terminations on the front face. Connection pitch is 35 mm. Compliance documentation covers IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. The breaker carries an IP20 finger-safe front and IK07 impact resistance per EN 50102. Category A utilization means it's not intended for motor starting duty where high inrush currents are routine — it's a distribution breaker, not a motor circuit protector. Mechanical durability is 10,000 cycles — fine for a main or feeder breaker that cycles a few times a year. Not the part for a frequent-switching application like a welding press or a capacitor bank that cycles daily. Dimensions: 105 mm wide, 165 mm high, 68 mm deep. That depth (68 mm) is the body depth behind the panel — important when fitting into a shallow enclosure or a backpanel with limited clearance to the rear wall.","metaTitle":"Schneider EasyPact EZCV250N3225 MCCB, 225 A, 20 kA at 440 V","metaDescription":"Schneider Electric EasyPact EZCV250N3225 molded case circuit breaker, 225 A rated current, 20 kA breaking capacity at 440 V AC. TM-D thermal-magnetic trip unit with earth-leakage p","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"68 mm","Width":"105 mm","Height":"165 mm","Standards":"EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Earth-leakage protection Short-circuit protection Overload protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"225 A at 40 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZCV250N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"225 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZCV250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"With","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"3t","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/345f3ac786fe3a37b477da30ecd02afb.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZCV250N3225/circuit-breaker-easypact-ezcv250n-tmd-225-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZCV250N3225/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZCV250N3225 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead time number is published here, but the supply channel is active."},{"question":"What is the breaking capacity of EZCV250N3225 at 440 V?","answer":"20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V it rises to 25 kA, and at 220–240 V it reaches 85 kA."},{"question":"What compliance documentation does EZCV250N3225 carry?","answer":"It conforms to EN/IEC 60947-2, GB/T 14048.2, EN/IEC 60947-1, and JIS C8201-2-2. It is suitable for isolation per IEC 60947-2 and carries IP20 and IK07 protection ratings."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250N3225","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250N3225 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}