{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250N4063","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250N4063","canonicalUrl":"https://aoctrl.com/schneider/EZCV250N4063","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250N4063","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250N, circuit breaker, 63 A, 4P, 20 kA Icu at 440 V AC, thermal-magnetic TM-D trip unit with earth-leakage protection, front connections, backplate mount.","salesMarkdown":"The Schneider Electric EZCV250N4063 is a 4-pole EasyPact EZCV250N moulded-case circuit breaker rated 63 A at 40 °C with a TM-D thermal-magnetic trip unit and integrated earth-leakage protection. Connection pitch is 35 mm, matching common busbar systems. IP20 finger-safe terminals are fine inside a closed panel; IK07 impact rating means it survives a tool drop during commissioning. ## Protection profile and compliance The TM-D trip unit covers overload and short-circuit protection on three poles (the neutral pole is unprotected, per the 3t configuration). Earth-leakage protection is built in — no add-on module needed. Standards compliance spans EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2, covering European, Chinese, and Japanese installations.","metaTitle":"Schneider Electric EZCV250N4063 EasyPact EZCV250N, 63 A, 20","metaDescription":"Schneider Electric EZCV250N4063 EasyPact EZCV250N circuit breaker. 63 A rated current, 20 kA Icu at 440 V AC, 4 poles, thermal-magnetic TM-D trip unit with earth-leakage protection","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"68 mm","Width":"140 mm","Height":"165 mm","Voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"35 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947","Temp Storage Max":"85 °C","Temp Storage Min":"-35 °C","Breaking Capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Insulation Voltage Ui":"440 V AC 50/60 Hz conforming to IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-35...85 °C","Connection Surface Top":"Front","Mechanical Life Cycles":"10000 cycles","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b9a31fb13523101468386a3a79b9d0de.pdf","sourceUrl":"https://www.se.com/ae/en/product/EZCV250N4063/circuit-breaker-easypact-ezcv250n-tmd-63-a-4-poles-4d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZCV250N4063/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250N4063","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250N4063 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}