{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZCV250N44160","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZCV250N44160","canonicalUrl":"https://aoctrl.com/schneider/EZCV250N44160","factsUrl":"https://aoctrl.com/api/mcp/products/EZCV250N44160","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZCV250N, MCCB, 160 A, 20 kA Icu at 440 V AC, 4 poles, TM-D thermal-magnetic trip unit, with earth-leakage protection.","salesMarkdown":"## 160 A MCCB with integrated earth-leakage protection The Schneider Electric EZCV250N44160 is a 4-pole EasyPact EZCV250N moulded-case circuit breaker rated at 160 A at 40 °C, fitted with a TM-D thermal-magnetic trip unit and built-in earth-leakage protection. It delivers a breaking capacity of 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, with higher ratings at lower voltages — 25 kA at 380–415 V and 85 kA at 220–240 V. This makes it a solid choice for distribution panels where fault levels stay under 20 kA at the service voltage, and the earth-leakage module saves a separate RCCB slot in the enclosure. The EZCV250N44160 ships as a complete breaker with the TM-D trip unit pre-installed and earth-leakage protection integrated. Mounting is fixed backplate with a 35 mm connection pitch between poles. The toggle handle gives positive contact indication — you see the contact state, not just the handle position. IP20 finger-safe terminals and IK07 impact resistance cover panel-side handling. No holes in the box: the kit includes the breaker, trip unit, and earth-leakage module as one assembly. ## Compliance and standards coverage The breaker carries approvals to GB/T 14048.2, EN/IEC 60947-1, JIS C8201-2-2, and EN/IEC 60947-2.","metaTitle":"Schneider Electric EZCV250N44160 EasyPact EZCV250N, 160 A, 2","metaDescription":"Schneider Electric EZCV250N44160 EasyPact EZCV250N MCCB. 160 A thermal-magnetic TM-D trip, 20 kA Icu at 440 V AC, 4 poles, earth-leakage protection. Current production, sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"68 mm","Width":"140 mm","Height":"165 mm","Standards":"GB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Short-circuit protection Overload protection Earth-leakage protection","lifecycle_stage":"current","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"EasyPact","Trip unit rating":"160 A at 40 °C","Breaking capacity":"20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Easypact EZCV250N","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"160 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Easypact EZCV250N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Mechanical durability":"10000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP20 conforming to IEC 60529","Earth-leakage protection":"With","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"Without protection","Protected poles description":"4t","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-35...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/610b4d6a2410458939a324943250532b.pdf","sourceUrl":"https://www.se.com/vn/en/product/EZCV250N44160/circuit-breaker-easypact-ezcv250n-tmd-160-a-4-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZCV250N44160/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy EZCV250N44160 and how do I get a price?","answer":"The EZCV250N44160 is available to order through independent industrial-automation distributors. Submit an RFQ for current pricing and availability — both are confirmed at quote time."},{"question":"What is EZCV250N44160's breaking capacity at 440 V?","answer":"The EZCV250N44160 delivers 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V it reaches 25 kA, and at 220–240 V it reaches 85 kA."},{"question":"What compliance documentation does this brand provide for EZCV250N44160?","answer":"The EZCV250N44160 is certified to GB/T 14048.2, EN/IEC 60947-1, JIS C8201-2-2, and EN/IEC 60947-2. It carries IP20 finger-safe protection and IK07 impact resistance. The manufacturer provides IEC 60947-2 declaration of conformity and test reports on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZCV250N44160","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZCV250N44160 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}