{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZS100E3040","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZS100E3040","canonicalUrl":"https://aoctrl.com/schneider/EZS100E3040","factsUrl":"https://aoctrl.com/api/mcp/products/EZS100E3040","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZS, EZS100E3040, 3-pole thermal-magnetic circuit breaker, 40 A at 40 °C, 25 kA Icu at 400 V AC, EN/IEC 60947-2.","salesMarkdown":"It is a distribution breaker (category A, no intentional short-time delay) built to EN/IEC 60947-2. At 240 V AC it handles 50 kA Icu. The front-front connection (both line and load from the front) and 25 mm connection pitch match standard panel layouts. The toggle control and fixed mounting on a backplate keep the installation straightforward.","metaTitle":"Schneider Electric EZS100E3040 EasyPact EZS 40A Thermal-Magn","metaDescription":"Schneider Electric EZS100E3040 EasyPact EZS circuit breaker, 40A rated, 3-pole, TM-D trip unit. 25 kA Icu at 400 V AC. EN/IEC 60947-2. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"75 mm","Height":"130 mm","Voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2","IP Rating":"IP40","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"690 V conforming to EN/IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-35 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-35...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b0870cf3752558bb2bf89d4e172c6366.pdf","sourceUrl":"https://www.se.com/th/en/product/EZS100E3040/circuit-breaker-easypact-ezs100e-with-tmd-trip-unit-40a-3p-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZS100E3040/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZS100E3040","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZS100E3040 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}