{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZS100F3050","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZS100F3050","canonicalUrl":"https://aoctrl.com/schneider/EZS100F3050","factsUrl":"https://aoctrl.com/api/mcp/products/EZS100F3050","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZS, circuit breaker, EZS100F3050, 3P, 50 A, TM-D trip unit, 60 kA Icu at 240 V AC, fixed backplate mount.","salesMarkdown":"## What this breaker does for a panel It's built for distribution duty in an AC network — think branch-circuit protection in a panel feeding motor control centers or lighting sub-distribution. The fixed backplate mount and front-front connections keep wiring predictable; the toggle handle is right there for manual switching. The F breaking-capacity code means 60 kA Icu at 240 V AC, 30 kA at 400 V, and 20 kA at 440 V — all per IEC 60947-2. That's enough to sit downstream of a larger main breaker without worrying about cascading failure. The integral instant protection is rated 500 kA, so the magnetic trip responds fast on a bolted fault. Category A utilization (no intentional short-time delay) means it's a standard distribution breaker, not a selective main. Pair it with a properly sized upstream device for full selectivity. Fixed backplate mount, 25 mm connection pitch. Neutral position is left, so plan your busbar layout accordingly.","metaTitle":"Schneider Electric EZS100F3050 EasyPact EZS, 50 A, 3-Pole, 6","metaDescription":"Schneider Electric EZS100F3050 EasyPact EZS circuit breaker, 50 A at 40 °C, 3-pole, thermal-magnetic TM-D trip unit, 60 kA Icu at 240 V AC. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"75 mm","Height":"130 mm","Voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2","IP Rating":"IP40","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"690 V conforming to EN/IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-35 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-35...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/67908ad8e6a26e7e86663e5dd193a59d.pdf","sourceUrl":"https://www.se.com/th/en/product/EZS100F3050/circuit-breaker-easypact-ezs100f-with-tmd-trip-unit-50a-3p-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZS100F3050/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZS100F3050","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZS100F3050 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}