{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZS100F3100","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZS100F3100","canonicalUrl":"https://aoctrl.com/schneider/EZS100F3100","factsUrl":"https://aoctrl.com/api/mcp/products/EZS100F3100","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZS, circuit breaker, EZS100F3100, 100 A, 3 poles, TM-D trip unit, 60 kA Icu at 240 V AC, 50/60 Hz.","salesMarkdown":"The 60 kA Icu at 220/240 V AC tells you the maximum fault current it can safely interrupt at that voltage level; at 380/400 V AC the breaking capacity drops to 30 kA Icu, which is the number you coordinate with your upstream protection. Fixed mounting on a backplate, front-connected both line and load sides. The 25 mm connection pitch matches standard busbar spacing for panelboard integration. Dimensions are 130 mm high, 75 mm wide, 60 mm deep — that 75 mm width is a three-pole footprint that fits a standard distribution panel cutout. Neutral position is left. IP40 enclosure protection keeps out tools and wires over 1 mm; IK07 impact resistance handles light mechanical shock during installation.","metaTitle":"Schneider Electric EZS100F3100 EasyPact EZS Circuit Breaker,","metaDescription":"Schneider Electric EZS100F3100 EasyPact EZS circuit breaker, 100 A rated current, 60 kA breaking capacity at 240 V AC, 3 poles, thermal-magnetic TM-D trip unit. Sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"60 mm","Width":"75 mm","Height":"130 mm","Voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2","IP Rating":"IP40","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"25 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Insulation Voltage Ui":"690 V conforming to EN/IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-35 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-35...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad33c8055618f35c910624ef3688259f.pdf","sourceUrl":"https://www.se.com/th/en/product/EZS100F3100/circuit-breaker-easypact-ezs100f-with-tmd-trip-unit-100a-3p-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZS100F3100/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZS100F3100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZS100F3100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}