{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"EZS630F3500","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"EZS630F3500","canonicalUrl":"https://aoctrl.com/schneider/EZS630F3500","factsUrl":"https://aoctrl.com/api/mcp/products/EZS630F3500","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric EasyPact EZS series, EZS630F3500, 3-pole circuit breaker, 500 A at 40 °C, TM-D thermal-magnetic trip unit, 40 kA Icu at 220/240 V AC, fixed mounting, front connections.","salesMarkdown":"The TM-D trip unit provides fixed long-time pickup at 1 In and a fixed instantaneous threshold of 5000 A, which is the magnetic trip point for short-circuit protection. For a distribution panel feeding a 500 A bus, this breaker sits as the main or a large feeder; the fixed trip settings mean no field adjustment — what you order is what protects the circuit. Breaking capacity is 40 kA Icu at 220/240 V AC and 36 kA Icu at 380/400 V AC, both per EN/IEC 60947-2. The 40 kA at 220 V covers North American 240 V split-phase distribution. Rated insulation voltage (Ui) is 690 V, and rated operational voltage (Ue) is 440 V AC. The 690 V Ui means the internal creepage and clearance distances are designed for a 690 V system, so the breaker can be used in 400/440 V circuits with full margin. Fixed mounting on a backplate, with front connections on both the line and load sides. Neutral is on the left, which matters when aligning with a pre-drilled busbar or a downstream neutral bar.","metaTitle":"Schneider Electric EZS630F3500 EasyPact EZS Circuit Breaker,","metaDescription":"Schneider Electric EZS630F3500 EasyPact EZS circuit breaker, 500 A rated current at 40 °C, 3-pole, TM-D trip unit, 40 kA breaking capacity at 220 V AC. Sourced to order against an","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"110 mm","Width":"182 mm","Height":"257 mm","Voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2","IP Rating":"IP40","Control Type":"Toggle","Product Status":"Active","Terminal Pitch":"45 mm","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-50 °C","Breaking Capacity":"40 kA Icu at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 220/230 V AC 50/60 Hz conforming to GB 14048.2 35 kA Icu at 440 V AC 50/60 Hz conforming to GB 14048.2","Insulation Voltage Ui":"690 V conforming to EN/IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-35 °C","Temperature Storage":"-50...85 °C","Connection Surface Top":"Front","Electrical Life Cycles":"8000 cycles 415 V In/2 conforming to EN/IEC 60947-2 8000 cycles 400 V In conforming to GB 14048.2","Mechanical Life Cycles":"15000 cycles conforming to EN/IEC 60947-2 10000 cycles conforming to GB 14048.2","Connection Surface Bottom":"Front","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-35...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0f7908db1cf6cd57b9b161a999e03671.pdf","sourceUrl":"https://www.se.com/th/en/product/EZS630F3500/circuit-breaker-easypact-ezs630f-with-tmd-trip-unit-500a-3p-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/EZS630F3500/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/EZS630F3500","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/EZS630F3500 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}