{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FR-A840-00470-2-60","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FR-A840-00470-2-60","canonicalUrl":"https://aoctrl.com/mitsubishi/FR-A840-00470-2-60","factsUrl":"https://aoctrl.com/api/mcp/products/FR-A840-00470-2-60","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi Electric FR-A800 series inverter, FR-A840-00470-2-60, 400V class, 470A SLD rated current, standard model, 15 kg.","salesMarkdown":"## 470 A SLD — sizing the drive for the load The FR-A840-00470-2-60 carries a 470 A SLD (Standard Light Duty) rated current at 400V class, which is the headline number for matching the drive to a motor nameplate. SLD rating typically applies to variable-torque loads like fans and pumps where the peak current stays below the drive's continuous rating. For constant-torque applications (conveyors, extruders), the HD (Heavy Duty) rating on the same frame would be lower — so confirm the duty cycle before committing the BOM line. This is a standard model (structure code 0), meaning no special options like built-in EMC filter or brake transistor — those are separate add-on modules. The -2 = CA type designation indicates the functional variant for the target region; the -60 suffix confirms circuit board coating (3C2) is present but plated conductor is not used, which matters for environments with mild condensation risk but not aggressive corrosive gas. ## Panel fit — 15 kg frame, DIN rail or floor mount The 400V class input accepts three-phase 380-480 VAC at 50/60 Hz. The drive's DC bus voltage will sit around 540-680 VDC depending on line conditions — factor this into the braking resistor selection if deceleration time is tight.","metaTitle":"Mitsubishi FR-A840-00470-2-60 Inverter, 470A SLD, 400V","metaDescription":"Mitsubishi FR-A840-00470-2-60 FR-A800 series inverter, 400V class, 470A SLD rated current, standard model. Active production, sourced to order. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Type":"-2 = CA","title":"FR-A840-00470-2-60","Weight":"15 Kg","Description":"00470 = SLD rated inverter current (A)","Product No.":"FR-A840-00470-2-60","description":"Inverter FR-A800 Series","Product Type":"Inverter FR-A800 Series","Voltage class":"4 = 400V class","Shipping Weight":"17 Kg","lifecycle_stage":"current","Estimated Lead Time":"Usually ships in 1-10 working days.","Structure, functionality":"0 = Standard model","Circuit board coating (3C2) & Plated conductor":"-60 = With & Not used"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,057.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/73da309b96ad9e252e5414d2263f7162.pdf","sourceUrl":null},"ai":{"faq":[{"question":"Can the FR-A840-00470-2-60 replace a FR-A740-05470-NA in an existing panel?","answer":"No — the FR-A740-05470-NA is a 200V class drive, while the FR-A840-00470-2-60 is 400V class. The input voltage, DC bus voltage, and motor winding insulation requirements are fundamentally different. A panel swap would require a new input transformer and possibly a different motor."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FR-A840-00470-2-60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FR-A840-00470-2-60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}