{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FR-E720-15K","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FR-E720-15K","canonicalUrl":"https://aoctrl.com/mitsubishi/FR-E720-15K","factsUrl":"https://aoctrl.com/api/mcp/products/FR-E720-15K","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi Electric FREQROL-E700 series, FR-E720-15K three-phase 200V inverter, 1.5 kW, 3.2 kVA, IP20.","salesMarkdown":"## Drive for a 1.5 kW motor on a 200 V line The Mitsubishi FR-E720-15K is a compact FREQROL-E700 inverter rated for a 1.5 kW three-phase induction motor at 240 V. Output capacity is 3.2 kVA, with a forced-air cooling system that keeps it running in ambient conditions down to -10 °C and up to 50 °C (40 °C in a fully enclosed panel). The enclosure is IP20, so it belongs inside a control cabinet away from dust and liquid ingress. Analog inputs accept 0–10 V, 0–5 V, or 4–20 mA, selectable per terminal. For network integration, the drive carries RS-485, CC-Link, LONWorks, DeviceNet, PROFIBUS-DPV0, and Modbus RTU—covering most industrial fieldbuses without an option card. The control method supports Soft-PWM and high carrier frequency PWM with V/F control, advanced magnetic flux vector, general-purpose magnetic flux vector, and optimal excitation control. That gives flexibility for fan/pump loads as well as constant-torque applications where slip compensation and droop control are needed. The FR-E720-15K is a mature product in Mitsubishi's FREQROL-E700 line. It is still in regular production, so there is no last-time-buy pressure. We source this inverter to order for BOM lines, with lead times quoted against your specific quantity request.","metaTitle":"Mitsubishi FR-E720-15K FREQROL-E700 Inverter, 1.5 kW, 240 V","metaDescription":"Mitsubishi FR-E720-15K FREQROL-E700 VFD, 1.5 kW, 3.2 kVA, 240 V, RS-485/CC-Link/DeviceNet/PROFIBUS/Modbus RTU, IP20, forced air cooling. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Type":"Simple and Powerful Compact Inverter FREQROL-E700 Series Three-phase 200 V","Manufacturer":"Mitsubishi Electric","Product name":"FR-E720-1.5K","Start signal":"Forward / reverse individual, start signal self-holding input (3 wire input) selectable","Communication":"RS-485, CC-Link, LONWorks, DeviceNet, PROFIBUS-DPV0, Modbus RTU","Digital input":"Input by operation panel, parameter unit","Cooling Method":"Forced wind cold","Product series":"FREQROL-E700","output-Voltage":"Three-phase 200 to 240 V","Rough mass (kg)":"1.4","Shipping Weight":"3 Kg","lifecycle_stage":"mature","Abnormal content":"Display the contents of abnormality when the protection function is operating, and store 8 times of the contents of abnormality","Estimated Lead Time":"Usually ships in 1 - 10 working days.","Environment -Atmosphere":"Indoor (corrosion gas, flammable gas, oil mist, no dust)","output-Rated current (A)":"8","Power supply-Voltage class":"Three-phase 200 V class","output-Rated capacity (kVA)":"3.2","Protection and alarm function":"Over current during acceleration, Over current during constant speed, Over current during deceleration, Over voltage during acceleration, Over voltage during constant speed, Over voltage during deceleration, Inverter protection thermal operation, Motor protection thermal operation, Fin overheating, Input phase loss, Start-up Output side ground fault overcurrent, output short circuit, output phase failure, external thermal operation, option error, parameter error, PU error, retry count over, CPU error, brake transistor error, rush resistance overheat, communication error, analog input error , USB communication error, brake sequence error 4 to 7 Fan failure, over current stall prevention, over voltage stall prevention, PU stop, parameter write error, regenerative brake pre alarm, electronic thermal pre alarm, maintenance output, under voltage","environment -Ambient humidity":"90% RH or less (without condensation)","Applicable motor capacity (kW)":"1.5 kW","output-Overload current rating":"150% 60s, 200% 3s (retarding time characteristics)","Protective structure (JEM 1030)":"Closed type (IP20), the fully closed series is IP40.","Control specification-DC braking":"Operating frequency (0 to 120 Hz), operating time (0 to 10 s), operating voltage (0 to 30%) variable","Environment -Storage Temperature":"-20 ° C to + 65 ° C","Input terminal selectable signal":"Multistage speed selection, remote setting, contact selection, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, brake release complete signal, external thermal input, PU-external operation switching, V / F switching, Selection from output stop, start self-hold selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switching, external-NET operation switching, command authority switching, inverter operation permission signal, PU operation external interlock","environment -Ambient temperature":"-10 ° C to + 50 ° C (without freezing) (-10 ° C to + 40 ° C in the case of fully closed structural specification)","Output terminal selectable signal":"During inverter operation, frequency arrival, overload alarm, output frequency detection, regenerative brake pre-alarm, electronic thermal pre-alarm, inverter operation preparation completed, output current detection, zero current detection, PID lower limit limit, PID upper limit limit, PID forward rotation reverse Output, brake release request, fan failure, FIN overheat pre-alarm, power failure decelerating, PID control in operation, retrying, life alarm, average current value monitor, remote output, light failure output, abnormal output, abnormal output 3, maintenance timer Select from alarm","Control specification-Torque boost":"Manual torque boost","Analog input terminal specification":"Terminal 2: 0 to 10 V, 0 to 5 V selectable Terminal 4: 0 to 10 V, 0 to 5 V, 4 to 20 mA selectable","Control specification-Digital input":"Within 0.01% of the set output frequency","Control specification-control method":"Soft-PWM control / high carrier frequency PWM control (V / F control, advanced magnetic flux vector control, general-purpose magnetic flux vector control, optimal excitation control can be selected)","environment -Elevation and vibration":"Less than 1000m above sea level 5.9m / s 2 or less","Control specification-Starting torque":"200% or more (at 0.5 Hz) ... When advanced flux vector control is set (3.7 K or less)","Output terminal (relay output) points":"1point","displaycontrol panelDriving condition":"Output frequency, motor current (steady), output voltage, frequency setting value, integrated energizing time, actual operation time, motor torque, converter output voltage, regenerative brake duty factor, electronic thermal load factor, output current peak value, converter output voltage peak Motor load factor, PID target value, PID measured value, PID deviation, inverter input / output terminal monitor, input / output terminal option monitor, output power, integrated power, motor thermal load factor, inverter thermal load factor selectable","Control specification-Torque limit level":"0 to 200%","Number of output terminals for indicator":"1 point","Operation specification-Driving function":"Upper / lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward / reverse rotation prevention, remote setting, brake sequence, second function, multistage speed operation, stop control, droop control, regeneration avoidance, Slip compensation, operation mode selection, off-line auto tuning function, PID control, computer link operation (RS-485)","Power supply-Power supply capacity (kVA)":"4.5","Control specification-Output frequency range":"0.2 to 400 Hz","Power supply-Frequency tolerance fluctuation":"± 5%","Power supply-AC voltage tolerance fluctuation":"170-264V 50Hz / 60Hz","Display terminal output terminal specifications":"FM: up to 2.4kHz","Power supply-Rated input AC voltage / frequency":"Three-phase 200 to 240 V 50 Hz / 60 Hz","input signalNumber of terminals (contact input)":"7 points","Display terminal output terminal selectable signal":"Output frequency, motor current (steady), output voltage, frequency setting value, motor torque, converter output voltage, regenerative brake usage rate, electronic thermal load factor, output current peak value, converter output voltage peak value, reference voltage output, motor load Select from rate, PID target value, PID measured value, output power. Pulse train output","Control specification-Frequency accuracyAnalog input":"Within ± 0.5% of maximum output frequency (25 ° C ± 10 ° C)","Frequency setting signalAnalog input terminal number":"2 points","Control specification-Stall prevention operation level":"Operating current level can be set (0 to 200% variable), can be selected","Control specification-Voltage / frequency characteristics":"Base frequency 0 to 400 Hz can be set arbitrarily, constant torque, reduced torque pattern selectable","Output terminal selectable signal (when option is installed)":"Output the same signal as the main unit","Control specification-Acceleration / deceleration time setting":"0.01 to 360s, 0.1 to 3600s (acceleration / deceleration can be set individually), linear or S-curve acceleration / deceleration mode selectable","Control specification-Frequency setting resolutionAnalog input":"0.06 Hz / 60 Hz (terminal 2, 4: 0 to 10 V / 10 bit), 0.12 Hz / 60 Hz (terminal 2, 4: 0 to 5 V / 9 bit), 0.06 Hz / 60 Hz (terminal 4: 4 to 20 mA / 10 bit)","Output signalNumber of output terminals (open collector output)":"2 points"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$389.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4360705e0cb8136fc63366f9e287088f.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/FR-E720-15K/alternatives.json"},"ai":{"faq":[{"question":"What fieldbus protocols does this drive support?","answer":"The drive includes RS-485, CC-Link, LONWorks, DeviceNet, PROFIBUS-DPV0, and Modbus RTU, all built-in without option cards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FR-E720-15K","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FR-E720-15K when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}