{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FRN0006G2S-4GU","brand":"Fuji Electric","brandSlug":"fuji-electric","productSlug":"FRN0006G2S-4GU","canonicalUrl":"https://aoctrl.com/fuji-electric/FRN0006G2S-4GU","factsUrl":"https://aoctrl.com/api/mcp/products/FRN0006G2S-4GU","rawCanonicalId":null},"summary":{"shortDescription":"Fuji Electric FRENIC-Eco series, FRN0006G2S-4GU, 3 hp VFD, 5.5 A output, 460V AC three-phase input, NEMA 1 open enclosure, HVAC application.","salesMarkdown":"## Drive selection memo — FRN0006G2S-4GU The Fuji Electric FRN0006G2S-4GU is a FRENIC-Eco series variable frequency drive sized for a 3 hp motor on a 460V AC three-phase supply. Maximum output current is 5.5 A, with an output frequency range of 0.1 to 120 Hz — suitable for variable-torque HVAC loads like fans and pumps where the 50% starting torque at 1 Hz is enough to break away a centrifugal impeller without oversizing. Input voltage range is 380V-480V AC +10% / -15%, so it holds regulation through the brown-end dips common on utility feeds. ## Protection and I/O complement Built-in protection covers motor thermal overload, drive thermal overload, overvoltage, undervoltage, phase failure, phase-to-phase and phase-to-ground short circuit, and over-braking — enough to meet the fault-coverage expectations of a UL508C-listed panel. No brake chopper included, but dynamic braking is enabled via the DC bus terminals if an external resistor is added. I/O complement: 7 digital inputs, 3 analog inputs, 5 digital outputs, 2 analog outputs. Accepts remote contact closure for start/stop, and the keypad offers LCD/LED display of motor speed, output frequency, current, voltage, alarm codes, and function parameters. Control is via keypad or remote, with variable-frequency control method. ## Compliance and physical fit Certified to UL508C (power conversion equipment), CSA C22.2 No.14, and EN50178-1997 (electronic equipment for power installations). These cover North American and European installation codes — the drive is accepted in UL-listed panels and CE-marked machinery without additional component-level approvals. Physical dimensions: 10-1/4 in height, 5-7/8 in width, 6-3/8 in depth. Blue heat-sink style. Open enclosure means no integral disconnects or bypass — plan for external branch-circuit protection and a separate bypass contactor if the spec calls for hand-off-auto.","metaTitle":"FRN0006G2S-4GU FRENIC-Eco VFD, 3 hp, 5.5 A, 460V AC","metaDescription":"FRN0006G2S-4GU FRENIC-Eco VFD, 3 hp, 5.5 A, 460V AC input, NEMA 1, HVAC-rated, UL/CSA/EN50178. Active production. Sourced to order per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Brand":"FUJI ELECTRIC","Color":"Blue","Style":"Heat Sink","Series":"FRENIC - Eco","Displays":"Motor Speed With Percent, Alarm Code, Menu, Function Code","Enclosure":"Open","Standards":"UL508C, C22.2 No.14, EN50178-1997","Input Type":"Analog; Digital","Protection":"Drive Thermal Overload; Motor Thermal Overload; Over breaking; Overvoltage; Phase Failure; Phase to Phase or Phase to Ground Short Circuit; Under voltage","Application":"HV AC","Output Type":"Analog; Digital","Control Type":"Keypad, Remote","Display Type":"LCD, LED","Input Voltage":"460V AC","Overall Depth":"6-3/8 in","Overall Width":"5-7/8 in","Torque @ 1 Hz":"50%","Control Method":"Variable Frequency Control","Input Phase AC":"Three","Output Voltage":"480V AC","Overall Height":"10-1/4 in","Digital Readout":"Output Frequency, Output Current, Output Voltage","Dynamic Braking":"Yes","Input Frequency":"50/60 Hz","Output Phase AC":"Three","Starting Torque":"50%","lifecycle_stage":"current","Enclosure Rating":"NEMA 1","Number of Inputs":"(7) Digital; (3) Analog","Number of Outputs":"(5) Digital; (2) Analog","Start/Stop Control":"Programmable","Torque Application":"Variable Torque","Input Voltage Range":"380V-480V AC +10% / -15%","Maximum Output Power":"3 hp","Output Voltage Range":"0V AC to 460V AC","Brake Chopper Included":"No","Ethernet Port Included":"No","Maximum Output Current":"5.5 A","Output Frequency Range":"0.1 to 120 Hz","With Bypass / No Bypass":"No Bypass","Accepts Input Control Signal":"Remote Contact","Adjustable Acceleration Time":"0 to 3,600 sec","Adjustable Deceleration Time":"0 to 3,600 sec","With Line Contactor / No Line Contactor":"No Line Contactor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/FRN0006G2S-4GU/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this drive carry?","answer":"It is certified to UL508C, CSA C22.2 No.14, and EN50178-1997. These cover North American and European installation standards."},{"question":"What is the output current and power rating?","answer":"Maximum output current is 5.5 A, corresponding to 3 hp at 460V AC. Output frequency range is 0.1 to 120 Hz."},{"question":"What is the input voltage requirement?","answer":"Three-phase 460V AC nominal, with an operating range of 380V-480V AC +10% / -15% at 50/60 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/fuji-electric/FRN0006G2S-4GU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/fuji-electric/FRN0006G2S-4GU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}