{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FRN0217G2W-4GU","brand":"Fuji Electric","brandSlug":"fuji-electric","productSlug":"FRN0217G2W-4GU","canonicalUrl":"https://aoctrl.com/fuji-electric/FRN0217G2W-4GU","factsUrl":"https://aoctrl.com/api/mcp/products/FRN0217G2W-4GU","rawCanonicalId":null},"summary":{"shortDescription":"Fuji Electric FRENIC-Eco series, FRN0217G2W-4GU, HVAC variable frequency drive, 150 hp, 203 A, 380-480 VAC three-phase input, NEMA 1 enclosure.","salesMarkdown":"## Drive selection memo for a 150 hp HVAC fan or pump The Fuji FRN0217G2W-4GU is a FRENIC-Eco series variable frequency drive sized for a 150 hp motor on 380-480 VAC three-phase, delivering up to 203 A continuous output. That 203 A rating is the full load ampacity you spec against the motor nameplate — if your fan or pump draws 190 A FLA at 460 V, this drive carries it with headroom. Output frequency spans 0.1 to 120 Hz, which covers the V/Hz curve for a standard induction motor driving a centrifugal load. It's built for variable-torque HVAC duty — fans, blowers, centrifugal pumps — where the load torque rises with speed squared. The 50% starting torque at 1 Hz tells you it'll break a fan loose without a big inrush event, but this isn't a constant-torque conveyor or extruder drive. Programmable start/stop and remote contact control let a BAS or building controller call the shots. NEMA 1 enclosure means it's for indoor, dry locations — no washdown, no outdoor weather. Overall it's 29-1/8 inches tall, 14 inches wide, 11-3/4 inches deep — plan the backplate real estate accordingly. No Ethernet port on this unit; control is via the keypad, remote contacts, and the analog/digital I/O. The LCD/LED display shows motor speed as a percent, output frequency, current, voltage, and alarm codes — enough for a field tech to see what the drive is doing without a laptop. Seven digital inputs and three analog inputs give you room for start/stop, speed reference, and feedback signals. Five digital and two analog outputs handle run status, fault relay, and speed follower signals back to the BMS. ## Protection and compliance package This drive carries its own protection suite: motor and drive thermal overload, overvoltage and undervoltage, phase failure, phase-to-phase and phase-to-ground short circuit, and overbraking detection. No brake chopper inside — if you need dynamic braking for overhauling loads, you add an external chopper and resistor. Standards listed are UL508C, CSA C22.2 No.14, and EN50178-1997 — it's accepted for North American and European industrial panels.","metaTitle":"Fuji FRN0217G2W-4GU FRENIC-Eco Drive, 150 hp, 203 A","metaDescription":"Fuji FRN0217G2W-4GU FRENIC-Eco HVAC drive, 150 hp, 203 A output, 380-480 VAC input, NEMA 1. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Brand":"FUJI ELECTRIC","Color":"Blue","Style":"Heat Sink","Series":"FRENIC - Eco","Displays":"Motor Speed With Percent, Alarm Code, Menu, Function Code","Enclosure":"Open","Standards":"UL508C, C22.2 No.14, EN50178-1997","Input Type":"Analog; Digital","Protection":"Drive Thermal Overload; Motor Thermal Overload; Over breaking; Overvoltage; Phase Failure; Phase to Phase or Phase to Ground Short Circuit; Under voltage","Application":"HV AC","Output Type":"Analog; Digital","Control Type":"Keypad, Remote","Display Type":"LCD, LED","Input Voltage":"460V AC","Overall Depth":"11-3/4 in","Overall Width":"14 in","Torque @ 1 Hz":"50%","Control Method":"Variable Frequency Control","Input Phase AC":"Three","Output Voltage":"480V AC","Overall Height":"29-1/8 in","Digital Readout":"Output Frequency, Output Current, Output Voltage","Dynamic Braking":"Yes","Input Frequency":"50/60 Hz","Output Phase AC":"Three","Starting Torque":"50%","lifecycle_stage":"current","Enclosure Rating":"NEMA 1","Number of Inputs":"(7) Digital; (3) Analog","Number of Outputs":"(5) Digital; (2) Analog","Start/Stop Control":"Programmable","Torque Application":"Variable Torque","Input Voltage Range":"380V-480V AC +10% / -15%","Maximum Output Power":"150 hp","Output Voltage Range":"0V AC to 460V AC","Brake Chopper Included":"No","Ethernet Port Included":"No","Maximum Output Current":"203 A","Output Frequency Range":"0.1 to 120 Hz","With Bypass / No Bypass":"No Bypass","Accepts Input Control Signal":"Remote Contact","Adjustable Acceleration Time":"0 to 3,600 sec","Adjustable Deceleration Time":"0 to 3,600 sec","With Line Contactor / No Line Contactor":"No Line Contactor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/FRN0217G2W-4GU/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"150 hp output power, 203 A maximum output current, 380-480 VAC three-phase input, 0.1 to 120 Hz output frequency range. It's a variable-torque HVAC drive with 50% starting torque at 1 Hz."},{"question":"What standards does this drive comply with?","answer":"UL508C, CSA C22.2 No.14, and EN50178-1997. It's suitable for North American and European industrial control panels."},{"question":"Does this drive include a brake chopper or Ethernet port?","answer":"No brake chopper is included, and no Ethernet port is on board. Dynamic braking requires an external chopper and resistor. Control is via keypad, remote contacts, and analog/digital I/O."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/fuji-electric/FRN0217G2W-4GU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/fuji-electric/FRN0217G2W-4GU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}