{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FRN0288G2W-2GU","brand":"Fuji Electric","brandSlug":"fuji-electric","productSlug":"FRN0288G2W-2GU","canonicalUrl":"https://aoctrl.com/fuji-electric/FRN0288G2W-2GU","factsUrl":"https://aoctrl.com/api/mcp/products/FRN0288G2W-2GU","rawCanonicalId":null},"summary":{"shortDescription":"Fuji Electric FRN Series, Compact/Heat Sink Style, FRN0288G2W-2GU, 100 hp, 283 A, 200-230V AC Three-Phase Input, 0-500 Hz Output, LCD/LED Keypad, IP00.","salesMarkdown":"The Fuji Electric FRN0288G2W-2GU is a 100 hp variable-frequency drive from the FRN series, delivering 283 A maximum output current on a 200 to 230V AC three-phase input. Output frequency spans 0 to 500 Hz, covering standard induction motors and higher-speed spindle applications. It ships as an open (IP00) enclosure with a compact/heat sink style — intended for panel mounting where the heat sink protrudes for airflow, not for standalone floor placement. The built-in LCD/LED keypad provides readouts for motor speed, output current, output frequency, and output voltage; the stop-key lockout prevents unauthorized shutdown. The 283 A maximum output current at 230V AC is the headline number — it governs the motor full-load amp rating. At 100 hp (approx 75 kW) on 230V, this drive is sized for a 100 hp 4-pole induction motor drawing around 240-250 A FLA, leaving headroom for overload. The 180% starting torque (presumably for 60 seconds) means it can break away high-inertia loads like centrifuges or crushers without oversizing. Constant and variable torque modes let it handle both conveyors (constant torque) and fans/pumps (variable torque) from the same unit. Dynamic braking is included, but no brake chopper is inside — you need an external braking resistor for overhauling loads. The Ethernet port supports networked monitoring or control; the 3 analog and 11 digital inputs plus 11 analog and 6 digital outputs give flexibility for feedback and sequencing without an expansion I/O module. The open (IP00) enclosure means it is designed for a clean, dry electrical enclosure — not for washdown or outdoor use. Overall dimensions are 29-1/8 in high by 14 in wide by 10-5/8 in deep.","metaTitle":"Fuji Electric FRN0288G2W-2GU FRN Series Drive, 100 hp, 283 A","metaDescription":"Fuji Electric FRN0288G2W-2GU FRN series drive, 100 hp, 283 A output, 200-230V AC three-phase input. UL 508C, EN61800-5-1. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drives (VFD)"],"specifications":{"Brand":"FUJI ELECTRIC","Color":"Blue","Style":"Compact/Heat Sink","Series":"FRN","Displays":"LCD/LED Keypad","Enclosure":"Open","Standards":"C22.2 No.14; EN61800-5-1:2007; UL 508C","Sub-brand":"Fuji Electric","Input Type":"Analog","Protection":"Overload Prevention Control","Application":"Mechanical Braking Control; Positioning Control","Output Type":"Digital","Control Type":"Keypad","Display Type":"LCD/LED","Input Voltage":"230V AC","Overall Depth":"10-5/8 in","Overall Width":"14 in","Control Method":"Keypad","Input Phase AC":"Three","Output Voltage":"230V AC","Overall Height":"29-1/8 in","Digital Readout":"Motor Speed; Output Current; Output Frequency; Output Voltage","Dynamic Braking":"Yes","Input Frequency":"50/60 Hz","Key Pad Lockout":"Stop Key","Output Phase AC":"Three","Starting Torque":"180%","lifecycle_stage":"current","Enclosure Rating":"IP00","Number of Inputs":"(3) Analog (11) Digital","Number of Outputs":"(11) Analog, (6) Digital","Start/Stop Control":"Manual","Torque Application":"Constant Torque; Variable Torque","Input Voltage Range":"200 to 230V AC","Maximum Output Power":"100 hp","Output Voltage Range":"200V AC to 230V AC","Brake Chopper Included":"No","Ethernet Port Included":"Yes","Maximum Output Current":"283 A","Output Frequency Range":"0 to 500 Hz","With Bypass / No Bypass":"No Bypass","Adjustable Acceleration Time":"0 to 6,000 sec","Adjustable Deceleration Time":"0 to 6,000 sec","With Line Contactor / No Line Contactor":"No Line Contactor"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/FRN0288G2W-2GU/alternatives.json"},"ai":{"faq":[{"question":"What compliance standards does FRN0288G2W-2GU meet?","answer":"It complies with UL 508C, EN61800-5-1:2007, and C22.2 No.14, covering North American and European drive safety and industrial control requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/fuji-electric/FRN0288G2W-2GU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/fuji-electric/FRN0288G2W-2GU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}