{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FRN050F1S-2DY","brand":"Fuji Electric","brandSlug":"fuji-electric","productSlug":"FRN050F1S-2DY","canonicalUrl":"https://aoctrl.com/fuji-electric/FRN050F1S-2DY","factsUrl":"https://aoctrl.com/api/mcp/products/FRN050F1S-2DY","rawCanonicalId":null},"summary":{"shortDescription":"Fuji Electric FRENIC-ECO Pump (F1-DY) drive, order code FRN050F1S-2DY, 50 HP, 230V 3-phase, current lifecycle stage.","salesMarkdown":"The Fuji FRN050F1S-2DY is a FRENIC-ECO Pump (F1-DY) drive rated for 50 HP on 230V three-phase input. This is the pump-specific variant of the FRENIC-ECO family — the firmware and I/O are tailored for centrifugal load profiles: quadratic V/f curve, PID sleep/wake for wet-well level control, and a built-in pump-cleaning cycle that briefly overspeeds the impeller to clear ragging. If you are retrofitting a lift-station or a constant-pressure booster set, this is the drive that ships with the pump macros pre-loaded. At 50 HP and 230V three-phase, this drive is sized for a 40–50 HP submersible or end-suction centrifugal pump — typical for a 6-inch to 8-inch discharge in a municipal lift station. The F1-DY firmware includes a dry-well detection input that can be wired to a float or conductivity probe; the drive will fault out before the pump runs dry and cooks the mechanical seal. The 230V class keeps you on a 208–240V service without a step-up transformer, which matters when the pump panel is fed from a 240V delta secondary. Mounts in a standard enclosure. Verify gland-plate clearance for the incoming 3-phase and motor leads.","metaTitle":"Fuji FRN050F1S-2DY FRENIC-ECO Pump Drive, 50 HP 230V 3-Phase","metaDescription":"Fuji FRN050F1S-2DY FRENIC-ECO Pump (F1-DY) drive, 50 HP, 230V 3-phase. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 240V"],"specifications":{"title":"FRN050F1S-2DY","description":"FUJ FRN050F1S-2DY CORE DRIVE|FUJ FRN050F1S-2DY CORE DRIVE FRENIC-ECO PUMP (F1-DY) 3PH 230V 050HP","lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/97e7cd5c03d9670c07274327850cb4a1.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is this drive designed for?","answer":"It is a FRENIC-ECO Pump (F1-DY) drive rated for 50 HP at 230V three-phase, with pump-specific firmware for centrifugal loads, PID sleep/wake, and pump-cleaning cycles."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/fuji-electric/FRN050F1S-2DY","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/fuji-electric/FRN050F1S-2DY when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}