{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FX2N-16EYT","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FX2N-16EYT","canonicalUrl":"https://aoctrl.com/mitsubishi/FX2N-16EYT","factsUrl":"https://aoctrl.com/api/mcp/products/FX2N-16EYT","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi FX2N series, output extension block, FX2N-16EYT, 16-point transistor sink output, 0.5 A/point resistive load, 0.2 ms response time.","salesMarkdown":"The Mitsubishi FX2N-16EYT is a 16-point transistor sink output extension block for the FX2N PLC series, giving you deterministic switching at 0.2 ms — fast enough to hold takt time on a high-speed weld line. Each point handles 0.5 A resistive load, but watch the common limits: 0.8 A per 4-point common, 1.6 A per 8-point common. ## Key electrical interface details Outputs are transistor sink type, driven by photocoupler isolation. ON voltage stays at 1.5 V or less; off-state leakage is 0.1 mA at DC 30 V. Response time is 0.2 ms or less for both on-to-off and off-to-on transitions at 200 mA, 24 VDC. That deterministic edge keeps cycle jitter off your takt-time budget. Power supply is drawn from the sequencer backplane (internal, no external supply needed for logic). External load supply can range from DC 5 V to 30 V. Withstand voltage between output terminals and earth is 500 VAC for 1 minute; insulation resistance is 5 MΩ or more at 500 VDC. Connection uses a vertical terminal block with M3 screws. LED indication on the panel lights when the photocoupler is driven — makes fault isolation at the cabinet door straightforward.","metaTitle":"Mitsubishi FX2N-16EYT 16-Point Transistor Output, 0.5 A/poin","metaDescription":"FX2N-16EYT end-of-life (EOL) 16-point transistor sink output, 0.2 ms response, 0.5 A/point. Source via RFQ for legacy FX2N systems.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Mass":"0.3 Kg","Frequency":"57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2","ON voltage":"1.5V or less","ON → OFF":"0.2 ms or less / 200 mA (24 VDC)","Manufacturer":"Mitsubishi Electric","Use altitude":"Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.","Rated voltage":"Internal power supply from the sequencer","Inductive load":"12 W / DC 24 V","Noise immunity":"Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si","Use atmosphere":"There is no corrosive property, flammable gas, conductive dust (dust) is not serious","Shipping Weight":"1.3 Kg","lifecycle_stage":"eol_hot","Impact resistance":"147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2","Relative humidity":"5 to 95% RH (noncondensing).... in operation","Withstand voltage":"Between the output terminal (transistor) of the expansion output block and the earth terminal: AC 500 V for 1 minute","Circuit insulation":"Photocoupler insulation","Ambient temperature":"0 to 55 ° C. ... Operating -25 to 75 ° C. ..... Save","Estimated Lead Time":"Usually ships in 1 - 10 working days.","Output type / format":"Transistor / sink output","Application sequencer":"FX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UCFX2NC - CNV - IF is required for connection to FX1NC and FX2NC. To connect to FX3GC, FX3UC, FX2NC - CNV - IF or FX3UC - 1PS - 5V is required.","External power supply":"DC 5V to 30V","Insulation resistance":"Between the output terminal (transistor) and the earth terminal of the expansion output block: 5 MΩ or more with DC 500 V insulation resistance meter","Number of output points":"16 points","Output connection shape":"Vertical terminal block (M3 screw)","Response time OFF → ON":"0.2 ms or less / 200 mA (24 VDC)","Maximum load Resistive load":"The total load current per 0.5 A / point common should be as follows. . Output 4 points / common: 0.8 A or less . Output 8 points / common: 1.6 A or less","Output operation indication":"LED on the panel when driving the photo coupler","Open-circuit leakage current":"0.1 mA / DC 30 V","Direct installation Frequency":"10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2","Anti-vibration When DIN rail is installed Frequency":"10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$119.00","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/FX2N-16EYT/alternatives.json"},"ai":{"faq":[{"question":"What is the response time of the FX2N-16EYT?","answer":"ON-to-OFF and OFF-to-ON are both 0.2 ms or less at 200 mA, 24 VDC, which keeps cycle times deterministic for high-speed automation."},{"question":"Can the FX3S-30MR/ES replace the FX2N-16EYT?","answer":"No. The FX3S-30MR/ES is a relay output CPU unit, not a transistor expansion block. It cannot be connected to an FX2N base without extensive rewiring and program changes."},{"question":"What is the maximum load per output point?","answer":"0.5 A resistive per point, but common limits apply: 0.8 A total per 4-point common, 1.6 A per 8-point common."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FX2N-16EYT","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FX2N-16EYT when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}