{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FX2N-232IF","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FX2N-232IF","canonicalUrl":"https://aoctrl.com/mitsubishi/FX2N-232IF","factsUrl":"https://aoctrl.com/api/mcp/products/FX2N-232IF","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi FX2N series, RS-232C interface module, FX2N-232IF, 0.3 kg, Class D grounding, DC 5V/24V power.","salesMarkdown":"## RS-232C interface for FX2N PLCs The Mitsubishi FX2N-232IF is an RS-232C communication interface module that mounts on FX2N series PLCs. It provides a full-duplex, non-procedural serial link at selectable speeds up to 19200 bps, with a D-SUB 9 pin male connector on the front panel. The module occupies 8 I/O points on the PLC bus. Power is drawn two ways: 40 mA at 5 VDC from the PLC backplane, plus 80 mA at 24 VDC ±10% from an external supply. Plan for the external 24 V feed in your panel wiring. ## Installation and grounding Ground per Class D: dedicated earth with resistance 100 Ω or less. The ground terminal is isolation-tested at 500 VAC for one minute against external terminals. Insulation resistance is 500 MΩ minimum at 500 VDC.","metaTitle":"Mitsubishi FX2N-232IF RS-232C Interface Module","metaDescription":"End-of-life RS-232C serial module for FX2N PLCs. DC 5V/24V power, D-SUB 9 pin, occupies 8 I/O points. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Mass":"0.3 kg","Ground":"Class D grounding (grounding resistance: 100 O or less) Grounding must be dedicated ground or common ground.","Frequency":"57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)","Manufacturer":"Mitsubishi Electric","Power supply":"DC 5 V 40 mA (internal power supply from PLC) DC 24 V ± 10% 80 mA (external power supply)","Use altitude":"Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.","Display (LED)":"RD, SD, POWER","Noise immunity":"Noise voltage with 1,000 Vp-p, noise width 1 µs, rising 1 ns, with noise simulator with period of 30 to 100 Hz","Use atmosphere":"There is no corrosive property, flammable gas, conductive dust (dust) is not serious","Shipping Weight":"2 kg","lifecycle_stage":"eol_hot","Insulation method":"Photocoupler insulation","Relative humidity":"5 to 95% RH (no condensation) · · · at operation","Withstand voltage":"Between external terminals and ground terminal: 500 VAC for 1 minute","Ambient temperature":"0 to 55 ° C. ··· Operating, -25 to 75 ° C. ····· Save","Communication Speed":"[No procedure] 300/600/1200/2400/4800/9600/19200 (bps)","Estimated Lead Time":"1 - 10 Working Days","Communication method":"Full duplex bidirection","Application sequencer":"FX 2 NC, FX 3 U, FX 2 NC, FX 3 UC FX 2 NC - CNV - IF is connected to FX 2 NC. To connect to FX 3 UC, FX 2 NC - CNV - IF or FX 3 UC - 1 PS - 5 V is required.","Insulation resistance":"Between external terminal and ground terminal: 500 MV DC 500 MO or more with insulation resistance meter","Transmission distance":"Maximum 15 m","Transmission standard":"RS-232C compliant","Communication procedure":"Non-procedural communication","Direct installation Frequency":"10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)","Number of occupied I / O points":"8 points (It can count either input or output)","External device connection method":"D-SUB 9 pin connector (male)","Anti-vibration When DIN rail is installed Frequency":"10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$150.00 – $228.05","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d7257970ce818ad217f7a31bfb1c5e2b.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/FX2N-232IF/alternatives.json"},"ai":{"faq":[{"question":"What is the mass of the FX2N-232IF?","answer":"The listed mass is 0.3 kg."},{"question":"What grounding is required for the FX2N-232IF?","answer":"It requires Class D grounding with a dedicated earth connection of 100 Ω or less."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FX2N-232IF","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FX2N-232IF when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}