{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FX2N-2LC","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FX2N-2LC","canonicalUrl":"https://aoctrl.com/mitsubishi/FX2N-2LC","factsUrl":"https://aoctrl.com/api/mcp/products/FX2N-2LC","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi Electric FX2N-2LC temperature adjustment block, FX2N series, 2-loop PID controller, CT input, EOL (end-of-life).","salesMarkdown":"## Temperature adjustment block for FX2N racks The FX2N-2LC is a dedicated temperature adjustment block that snaps onto a Mitsubishi FX2N PLC rack, adding two loops of PID temperature control without consuming the CPU's main scan cycle. Operation mode is selected via buffer memory: mode 0 is measured value monitor only, mode 1 adds a temperature alarm, and mode 2 adds full PID control — so the same block serves as a monitor-only card or a closed-loop controller depending on the application. ## Measurement accuracy and sensor compatibility Heater current is monitored via an external CT: with a CTL-12 the range is 0.0 to 100.0 A; with a CTL-6 it is 0.0 to 30.0 A — useful for detecting heater burnout in electric furnaces or extruder zones. ## Environmental and electrical ratings Vibration resistance follows IEC 61131-2: 57 to 150 Hz at 9.8 m/s² acceleration, and 10 to 57 Hz at 0.075 mm single amplitude, applied in each of X, Y, Z directions ten times (80 minutes total per axis). Noise immunity is tested to 1,000 Vp-p with 1 μs pulse width and 1 ns rise time, using a 30 to 100 Hz noise simulator. Grounding must be Type D (100 Ω or less) and dedicated — do not share a ground with high-power equipment. Withstand voltage between analog input and ground is AC 500 V for 1 minute; insulation resistance is 5 MΩ or more at DC 500 V.","metaTitle":"Mitsubishi FX2N-2LC Temperature Adjustment Block, EOL","metaDescription":"Mitsubishi FX2N-2LC temperature adjustment block for FX2N PLCs. EOL (end-of-life). Sourced to order. ±0.3% accuracy, CT input for heater current. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Frequency":"57 to 150 HzAcceleration: 9.8 m / s 2 X, Y, Z each 10 times (total 80 minutes each)","Manufacturer":"Mitsubishi Electric","Operation mode0":"Measured value monitor 1: Measured value monitor + temperature alarm 2: Measured value monitor + temperature alarm + control (selected by buffer memory)","Shipping Weight":"2 Kg","lifecycle_stage":"eol_hot","Estimated Lead Time":"1 - 10 Working Days","Direct mountingFrequency":"10 to 57 HzSingle amplitude: 0.075 mm X, Y, Z each direction 10 times (total 80 minutes each)","Noise resistantNoise voltage":"1,000 Vp-p, noise width: 1 μs, rise time: 1 ns, period: 30 to 100 Hz noise simulator","memoryBuilt-in EEPROM (number of rewrites":"100,000 times)","groundType D Grounding (Grounding resistance":"100 Ω or less) < Do not connect to a common ground with a high-power system> Connect a dedicated ground or shared ground.","Vibration resistanceWhen mounting DIN railFrequency":"10 to 57 HzSingle amplitude: 0.035 mm X, Y, Z each direction 10 times (total 80 minutes each)","Measurement accuracyAmbient temperature 23 ° C ± 5 ° C":"Input range ± 0.3% ± 1 digit Ambient temperature 0 ° C to 55 ° C: Input range ± 0.7% ± 1 digit However, B input 0 to 399 ° C (0 to 799 ° F) and PLII , 0 to 32 ° F of WRe5-26 input is out of guaranteed accuracy range","Withstand voltageBetween analog input terminal and ground terminal":"AC500V 1 minute","Insulation resistanceBetween analog input terminal and ground terminal":"5 MΩ or more with DC 500 V insulation resistance tester","Current detector (CT) input (heater current measurement value)When using CTL-12":"0.0 to 100.0 A When using CTL-6: 0.0 to 30.0 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$169.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5100c33a544f9975f39a01acdd51e23e.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/FX2N-2LC/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the FX2N-2LC and how do I get a price?","answer":"The FX2N-2LC is sourced through independent distribution channels."},{"question":"What is the FX2N-2LC used for?","answer":"It is a temperature adjustment block for Mitsubishi FX2N PLCs, providing two loops of PID temperature control with selectable operating modes (monitor, alarm, or full control) and heater current monitoring via an external CT."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FX2N-2LC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FX2N-2LC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}