{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FX2N-32ER-ES/UL","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FX2N-32ER-ES-UL","canonicalUrl":"https://aoctrl.com/mitsubishi/FX2N-32ER-ES-UL","factsUrl":"https://aoctrl.com/api/mcp/products/FX2N-32ER-ES%2FUL","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi FX2N-32ER-ES/UL, FX2N series base unit with 16 inputs / 16 relay outputs on removable M3 terminal blocks, AC 100–240 V supply at 30 W, currently flagged EOL/hot.","salesMarkdown":"The Mitsubishi FX2N-32ER-ES/UL is a compact brick PLC in the FX2N family — a base unit carrying 16 inputs and 16 relay outputs on removable M3 screw terminal blocks, with the CPU, supply and I/O all in one housing rather than a rack or backplane design. It runs on AC 100–240 V at 50/60 Hz, tolerates 85–264 V on the mains, and draws 30 W — internal supply is fused at 250 V 3.15 A — so a single cabinet feed covers the unit without an external 24 VDC PSU for the CPU. Programming sits on the FX1N / FX2N / FX3G / FX3U application sequencer toolchain, which means existing project files and ladder libraries carry across the family without a translator step. Built to slot into a standard industrial cabinet: 0 to 55 °C operating, 5–95 % RH non-condensing, vibration and shock qualified per IEC 61131-2, and rated for use only below 2000 m altitude. ## Inputs and outputs — what they actually switch Inputs are sink/source compatible, accept no-voltage contact or NPN/PNP open-collector drivers at 24 VDC ±10 %, draw about 5 mA per point at 24 VDC through a 4.3 kΩ input impedance, and are photocoupler-isolated from the logic — so a 3-wire PNP prox or a 2-wire contact drops on without a polarity jumper. Minimum load is DC 5 V 2 mA, which is the reference figure for keeping a high-impedance input stage in the ON state; below that the input may not register reliably. Relay outputs are rated 80 VA inductive per point, with external switching envelope up to 240 VAC / 30 VDC (250 VAC where CE/UL/cUL does not apply), which covers solenoid valves, contactors and small motor contactor coils but not large motor starters directly. Both input ON→OFF and OFF→ON response are about 10 ms, set by the input filter and the relay mechanical time — fast enough for limit switches and proximity sensors, slow enough that high-speed counting belongs on a dedicated high-speed input module. Insulation is mechanical on the output relays and photocoupler on the inputs; the supply-to-earth withstand is 1500 VAC for 1 minute and the I/O-to-earth 500 VAC for 1 minute, with insulation resistance ≥500 MΩ at 500 VDC. Mains inrush peaks at 40 A at 100 V or 60 A at 200 V for ≤5 ms — a standard Type B or C breaker on the cabinet feed handles it, but the supply fuse inside the unit is 250 V 3.15 A. ## Electrical environment and noise Grounding requires Class D grounding at 100 Ω or less, dedicated or common ground — the unit must share a low-impedance earth return with the rest of the panel for the noise and isolation figures to hold. Ambient atmosphere must be free of corrosive gas, flammable gas and conductive dust, consistent with general-purpose industrial cabinets; sealed or purged enclosure is needed for harsh process areas. ## Lifecycle — what EOL/hot means for sourcing For a running line, that means the move is to lock in a multi-year spare allocation through a stocking partner now; for a new design, the equivalent going-forward base unit in the FX family is the natural platform to specify rather than committing new production to an EOL base.","metaTitle":"Mitsubishi FX2N-32ER-ES/UL PLC, 16DI/16DO relay, AC 100-240V","metaDescription":"Mitsubishi FX2N-32ER-ES/UL is EOL/hot: 16 inputs / 16 relay outputs, AC 100-240 V supply, 30 W, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Mass":"0.65 Kg","Ground":"Class D grounding (grounding resistance: 100 Ω or less)Grounding should be dedicated ground or common ground.","Frequency":"57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2","ON → OFF":"About 10 ms","Input format":"Sink / source","Manufacturer":"Mitsubishi Electric","Minimum load":"DC 5 V 2 mA (reference value)","Use altitude":"Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.","Rated voltage":"AC 100 V to 240 V","Inductive load":"80VA","Inrush current":"AC 100 V: maximum 40 A 5 ms or less AC 200 V: maximum 60 A 5 ms or less","Noise immunity":"Noise voltage with 1,000 Vp-p, noise width 1 μs, rising 1 ns, with noise si","Use atmosphere":"There is no corrosive property, flammable gas, conductive dust (dust) is not serious","Input impedance":"4.3 kΩ","Rated frequency":"50/60 Hz","Shipping Weight":"1.7 Kg","lifecycle_stage":"eol_hot","Impact resistance":"147 m / s 2 , working time 11 ms, criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2","Power Consumption":"30 W","Power supply fuse":"250 V 3.15 A (3A)","Relative humidity":"5 to 95% RH (noncondensing).... in operation","Withstand voltage":"Between the power supply terminal (AC power supply) and the earth terminal: AC 1500 V for 1 minute 24 VDC Service power supply and between the input terminal (24 VDC) and the earth terminal: 500 V AC for 1 minute Between the output terminal (relay)","Circuit insulation":"Mechanical insulation","Ambient temperature":"0 to 55 ° C. ... Operating -25 to 75 ° C. ..... Save","Estimated Lead Time":"Usually ships in 1 - 10 working days.","Input response time":"About 10 ms","Input signal format":"Sink: no-voltage contact input or NPN open collector transistor contact input or PNP open collector transistor","Input signal current":"5 mA / 24 VDC","Input signal voltage":"DC 24 V ± 10%","Output type / format":"relay","Application sequencer":"FX1N, FX3G, FX2N, FX3U","External power supply":"DC 30 V or less AC 240 V or less (When not compliant with CE, UL, cUL standard, AC 250 V or less)","Insulation resistance":"Between each terminal and earth terminal: 500 MV DC 500 MΩ or more with an insulation resistance meter","Input connection shape":"Removable terminal block (M3 screw)","Number of input points":"16 points","Input operation display":"LED on the panel when input is ON","Number of output points":"16 points","Output connection shape":"Removable terminal block (M3 screw)","Voltage tolerance range":"AC 85V ~ 264V","Input circuit insulation":"Photocoupler insulation","Response time OFF → ON":"About 10 ms","24 VDC service power supply":"24 VDC 250 mA or less When input / output expansion block is connected, 24 VDC service power is consumed.","Maximum load Resistive load":"Please set the total load current per 2A / 1 point common as follows. . Output 4 points / common: 8 A or less","Output operation indication":"LED lit when relay coil is energized","Input ON sensitivity current":"3.5 mA or more","Direct installation Frequency":"10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2","Input OFF sensitivity current":"1.5 mA or less","Anti-vibration When DIN rail is installed Frequency":"10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The criteria are based on IEC 61131-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$449.00 – $935.11","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/FX2N-32ER-ES%2FUL/alternatives.json"},"ai":{"faq":[{"question":"What supply voltage and power does the FX2N-32ER-ES/UL need?","answer":"AC 100–240 V at 50/60 Hz, tolerating 85–264 V, drawing 30 W."},{"question":"How many inputs and outputs does the FX2N-32ER-ES/UL have and what output type?","answer":"16 inputs and 16 outputs, with outputs as relay contacts on removable M3 terminal blocks."},{"question":"What is the relay output switching envelope?","answer":"80 VA inductive per point, with external switching up to 240 VAC / 30 VDC (250 VAC where CE/UL/cUL does not apply)."},{"question":"How is the FX2N-32ER-ES/UL sourced?","answer":"Through an RFQ against broker and surplus-stock availability, since the part is eol_hot rather than current factory production."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FX2N-32ER-ES-UL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FX2N-32ER-ES-UL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}