{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FX3U-16CCL-M","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FX3U-16CCL-M","canonicalUrl":"https://aoctrl.com/mitsubishi/FX3U-16CCL-M","factsUrl":"https://aoctrl.com/api/mcp/products/FX3U-16CCL-M","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi FX3U-16CCL-M, CC-Link system master block, FX3U series, 8 remote device + intelligent device stations, 24 VDC 240 mA, DIN rail mountable.","salesMarkdown":"The Mitsubishi FX3U-16CCL-M is a CC-Link system master block for the FX3U series, handling up to eight remote device stations plus intelligent device stations. It runs CC-Link Ver.2.00 with backward compatibility to Ver.1.10, and transmission speed is selectable from 156 kbps up to 10 Mbps via the rotary switch. The module draws 240 mA from a 24 VDC external supply and occupies 8 I/O points on the base PLC. The CC-Link Ver.2.00 support means the master can handle expanded cyclic data per station compared to Ver.1.10 — useful if your remote stations are Ver.2-capable devices. The five selectable baud rates (156 kbps to 10 Mbps) let you trade speed for cable length; at 156 kbps the maximum total extension is 1200 m, while at 10 Mbps the distance shortens. The module's station number is fixed at 0 via the rotary switch, so it always occupies the master position on the link.","metaTitle":"Mitsubishi FX3U-16CCL-M CC-Link Master Module, 8 Stations","metaDescription":"Mitsubishi FX3U-16CCL-M CC-Link system master block. Supports Ver.2.00 and Ver.1.10. 24 VDC, 240 mA. 8 remote device + intelligent device stations. Mature lifecycle; sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"title":"FX3U-16CCL-M","Weight":"0.3 Kg","Frequency":"57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)","Product No.":"FX3U-16CCL-M","description":"FX3U16CCLM COMMUNICATION MODULE FX3U SERIES CC-LINK MASTER MODULE CC-LINK VERSION: 2.00 (VERSION 1 SUPPORTED) 8 REMOTE DEVICE STATIONS + INTELLIGENT DEVICE STATIONS 24 VDC 240 MA DIN RAIL MOUNTABLE","Product type":"CC-Link system master block","RAS function":"Automatic return function, Slave station detachment function, Abnormality detection by link special relay / register","Station type":"Master station (local station, standby master station function not available)","Coding scheme":"NRZI system","Display (LED)":"RUN, ERR., L RUN, L ERR. , SD, RD, POWER","Station number":"0 (set with rotary switch)","CC-Link version":"Ver.2.00 (Ver.1.10 is also supported)","Shipping Weight":"1.5 kg","lifecycle_stage":"mature","Connection cable":"CC-Link dedicated cable / Ver. 1.10 compatible CC-Link dedicated cable CC-Link dedicated cable, CC-Link dedicated high-performance cable, Ver.1.10 compatible CC-Link dedicated cable It can Be Mixed Not. Also, Please Attach A Terminating Resistor Matching The Type Of Cable.","Transmission speed":"156 kbps / 625 kbps / 2.5 Mbps / 5 Mbps / 10 Mbps selectable (set with rotary switch)","Current consumption":"24 VDC external power supply: 240 mA","Estimated Lead Time":"1 - 10 Working Days","Transmission format":"HDLC compliant","Communication method":"Broadcast polling method","Error control method":"CRC (X 16 + X 12 + X 5 + 1)","Application sequencer":"FX3U -16CCL-M, FX2N-16CCL-M can not be used with FX2N-32ASI-M in combination with FX5U, FX5UC, FX3G, FX3U (Ver.2.20 or later), FX3GC, FX3UC (Ver.2.20 or later) .","Internal power supply":"5 V DC 5 V of the sequencer is not used. (24 VDC external power supply is converted to DC 5 V and power is supplied.) Please observe the power supply turning on timing and procedure and use it.","Synchronization method":"Frame synchronization method","Transmission path format":"Bus (RS-485)","FX 3 G / FX 3 GC Sequencer":"32 Number of stations of remote I / O station 128 points","Number of links per station":"32 points Remote register (RWw): 4 points (Master station Remote device station / Intelligent device station) Remote register (RWr): 4 points (Remote device station / Intelligent device station Master Station) . The Above Is The Number Of Link Points In Remote Net Ver.1 Mode Refer To \"FX 3 U - 16 CCL - M User 'S Manual (JY 997 D 43501)\" For The Number Of Link Points In Remote Net Ver. 2 mode and Remote Net Addition mode.","Direct installation Frequency":"10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)","Communicate with the sequencer":"Execute via buffer memory with FROM / TO instruction or direct specification of buffer memory (FX3U / FX3UC).","Number of occupied I / O points":"8 points (It can count either input or output)","Power supply External power supply":"DC 24 V + 20% - 15% ripple (pp) within 5%","Class D grounding (grounding resistance":"100 O or less) Grounding must be dedicated ground or common ground.","Between all terminals and ground terminal":"500 MV DC 500 MO or more with an insulation resistance meter","Anti-vibration When DIN rail is installed Frequency":"10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)","Remote device station + intelligent device station total":"Up to 8 stations (total score of RX / RY is 256 or less each)","Maximum number of connected stations Remote I / O station":"Up to 8 stations (occupying the real I / O 32 points of the sequencer per one station)","Maximum cable total extension (maximum transmission distance)":"Different according to transmission speed up to 1200 m","Ambient temperature Relative humidity Impact resistance Noise immunity Withstand voltage Insulation resistance ground Use atmosphere Use altitude":"0 to 55 o C. &bull&bull&bull Operating -25 to 75 o C. &bull&bull&bull&bull&bull Save, : 5 to 95% RH (noncondensing)&bull&bull&bull&bull in operation."}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$104.40","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f61413bea29f83cdd247f08e04334ce0.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the closest functional second-source to the FX3U-16CCL-M?","answer":"The FX3S-20MR/ES is a different product class — a PLC CPU with relay outputs, not a CC-Link master module. It is not a functional second-source for the FX3U-16CCL-M. For a CC-Link master, stick with this Mitsubishi module or a compatible third-party master from another brand."},{"question":"Will the FX3U-16CCL-M drop into a panel specified around the FX3S-20MR/ES without rewiring?","answer":"No. The FX3S-20MR/ES is a PLC CPU with integrated I/O, while the FX3U-16CCL-M is a communication module that mounts on the FX3U base. They serve different roles and have different wiring and power requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FX3U-16CCL-M","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FX3U-16CCL-M when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}