{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FX3U-64CCL","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FX3U-64CCL","canonicalUrl":"https://aoctrl.com/mitsubishi/FX3U-64CCL","factsUrl":"https://aoctrl.com/api/mcp/products/FX3U-64CCL","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi Electric FX3U-64CCL CC-Link intelligent device station, Ver.2.00, 10 Mbps transmission speed, 220 mA current consumption, 0.3 kg mass, Class D grounding.","salesMarkdown":"## CC-Link node for FX3U racks The FX3U-64CCL is a CC-Link intelligent device station that mounts on the FX3U series PLC backplane, converting the local rack into a remote node on a CC-Link fieldbus network. It supports Ver.2.00 and is backward-compatible with Ver.1.10, so it drops into existing CC-Link segments without a firmware upgrade on the master. Transmission speed is selectable from 156 Kbps up to 10 Mbps, with the maximum cable length following the CC-Link specification for the chosen rate. The station number and number of occupied stations (1 to 4) are set via rotary switches on the module face. ## Power, grounding, and isolation The module draws 220 mA from the 24 VDC external supply; the internal 5 V rail from the PLC backplane is not used. Grounding must be Class D with a resistance of 100 Ω or less, and common grounding with high-voltage equipment is not allowed — a dedicated ground wire to the panel earth bar is the standard practice. The network bus is photocoupler-isolated from the internal power supply, with a 500 VAC withstand voltage for one minute between all terminals and ground. This keeps the CC-Link bus electrically separate from the PLC logic, reducing the risk of ground loops in mixed-voltage cabinets. Rated for 0 to 55 °C operating ambient, 5 to 95% RH noncondensing, and vibration per the 10–57 Hz / 0.075 mm amplitude profile when DIN-rail mounted. The module is not rated for use above 2000 m altitude without pressurization — a constraint for high-altitude installations.","metaTitle":"Mitsubishi Electric FX3U-64CCL CC-Link Intelligent Device","metaDescription":"Mitsubishi Electric FX3U-64CCL CC-Link intelligent device station, mature lifecycle. Supports Ver.2.00, 10 Mbps max, 220 mA consumption.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Mass":"0.3 kg","title":"FX3U-64CCL","Ground":"Class D grounding (grounding resistance: 100 O or less) <Common grounding with high voltage system is not allowed>","Frequency":"57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)","description":"Programmable Controllers MELSEC","Power supply":"DC 5 V internal power supply: DC 5 V of the programmable controller is not used. (DC 5 V is converted from 24 VDC external power supply)","Station type":"Intelligent device station","Use altitude":"Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.","Coding scheme":"NRZI system","Display (LED)":"RD, SD, RUN, ERR., L RUN, L ERR., POWER","Noise immunity":"Noise voltage with 1,000 Vp-p, noise width 1 µs, rising 1 ns, with noise simulator with period of 30 to 100 Hz","Station number":"1 to 64 stations (set with rotary switch)","Use atmosphere":"There is no corrosive property, flammable gas, conductive dust (dust) is not serious","CC-Link version":"Ver.2.00 (Ver.1.10 is also supported)","Shipping Weight":"2 kg","lifecycle_stage":"mature","Connection cable":"CC-Link dedicated cable, CC-Link exclusive high-performance cable, Ver. 1.10 compatible CC-Link dedicated cable","Impact resistance":"147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse","Insulation method":"The network bus and the internal power supply are photocoupler isolated","Relative humidity":"5 to 95% RH (noncondensing) · · · · in operation","Withstand voltage":"Between all terminals and ground terminal: 500 VAC for 1 minute","Transmission speed":"156 Kbps / 625 Kbps / 2.5 Mbps / 5 Mbps / 10 Mbps","Ambient temperature":"0 to 55 ° C. ··· Operating -25 to 75 ° C. ····· Save","Current consumption":"220 mA","Estimated Lead Time":"1 - 10 Working Days","Transmission format":"HDLC compliant","Communication method":"Broadcast polling method","Error control method":"CRC (X 16 + X 12 + X 5 + 1)","Application sequencer":"FX5U, FX5UC, FX3G, FX3U, FX3GC, FX3UC (Ver. 2.20 SER No.55 **** after May 2005 product)","Insulation resistance":"Between all terminals and ground terminal: 500 MV DC 500 MO or more with an insulation resistance meter","Synchronization method":"Flag synchronization method","Transmission path format":"Bus (RS-485)","Number of occupied stations":"1 to 4 stations (set with rotary switch)","24 VDC external power supply":"Power is supplied from the external terminal block. (+ 20% - 15% ripple (pp) within 5%)","Remote register point number":"The number of remote registers per station is 4 RW write areas, 4 RW read areas. (There are 1 to 8 times setting depending on extended cyclic setting)","Direct installation Frequency":"10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)","Number of remote I / O points":"The number of remote I / O points per station is 32 input points and 32 output points. (There is set by the extended cyclic setting of 1 to 8 times)","Communicate with the sequencer":"Perform through the buffer memory with the FROM / TO instruction (or directly designate the buffer memory)","Number of occupied I / O points":"8 points (It can count either input or output)","Allowable momentary power outage time":"PS 1: Continue operation against momentary power failure of 1 ms or less","Anti-vibration When DIN rail is installed Frequency":"10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)","Maximum cable total extension (maximum transmission distance)":"According to CC-Link specification."}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$191.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9dc723f83de6096f676b03d6bd5d5fd5.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the FX3U-64CCL used for?","answer":"It is a CC-Link intelligent device station that connects an FX3U-series PLC as a remote node on a CC-Link fieldbus network, handling up to 32 input and 32 output points per station with extended cyclic settings up to 8 times."},{"question":"How do I get current pricing and availability for FX3U-64CCL?","answer":"Submit an RFQ through the storefront; lead time and volume pricing are provided in the quotation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FX3U-64CCL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FX3U-64CCL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}