{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"FX3U-ENET-ADP","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"FX3U-ENET-ADP","canonicalUrl":"https://aoctrl.com/mitsubishi/FX3U-ENET-ADP","factsUrl":"https://aoctrl.com/api/mcp/products/FX3U-ENET-ADP","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi Electric FX3U-ENET-ADP Ethernet Interface Block, RJ45, 100 Mbps or 10 Mbps, full/half duplex, 30 mA at 5 VDC, 0.1 kg.","salesMarkdown":"## Controller compatibility and network fit The FX3U-ENET-ADP is an Ethernet interface block that adds a 100BASE-TX / 10BASE-T port to Mitsubishi FX3-series PLCs. It mounts directly on the basic unit, occupying one communication channel slot. Compatibility is version-specific: FX3U requires firmware V3.10 or later; FX3G and FX3GC need V2.00 or later. FX3S requires the FX3S-CNV-ADP adapter, and FX3G requires the FX3G-CNV-ADP adapter. On the FX3UC-32MT-LT(-2), a function expansion board is mandatory. Data rate is 100 Mbps or 10 Mbps, auto-negotiated, full or half duplex. Maximum segment length is 100 m per the 100BASE-TX standard. Cascade depth is limited to two stages with a repeater hub on 100BASE-TX, four stages on 10BASE-T. ## Power budget and environmental limits The block draws 30 mA from the 5 VDC rail of the basic unit — no separate power supply needed. This load must be factored into the base PLC's internal power budget. Operating temperature range is 0 to 55 °C, storage -25 to 75 °C, with 5–95% RH non-condensing. Vibration resistance when DIN-rail mounted is 0.035 mm half-amplitude at 10–57 Hz, and 9.8 m/s² acceleration at 57–150 Hz. Withstand voltage between all terminals and ground is 500 VAC for one minute; insulation resistance is 5 MΩ minimum at 500 VDC. ## Sourcing and lifecycle status Sourced and quoted to order against the BOM quantity.","metaTitle":"Mitsubishi Electric FX3U-ENET-ADP Ethernet Interface Block","metaDescription":"Mitsubishi Electric FX3U-ENET-ADP Ethernet Interface Block for FX3S/FX3G/FX3U series PLCs. 100 Mbps, RJ45, 30 mA at 5 VDC. Mature lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"title":"FX3U-ENET-ADP","Weight":"0.1 Kg","Apply PLC":"FX3S, FX3G (V2.00 or later), FX3U (since V3.10), FX3GC (V2.00 or later), FX3UC (V3.10 or later) connection to the FX3S is required FX3S-CNV-ADP. Connection to the FX3G is required FX3G-CNV-ADP. FX3U, connection to the FX3UC-32MT-LT (-2), you must have the function expansion board.","Connector":"RJ45","Frequency":"57 ~ 150Hz: Acceleration: 9.8m / s2 X, Y, Z each direction 10 times (for a total of each 80 minutes)","Anti-noise":"Noise voltage 1,000Vp-p, noise width 1µs, due to rising 1ns, cycle 30 ~ 100Hz of noise simulator","Product No.":"FX3U-ENET-ADP","description":"Ethernet Interface Block","Power supply":"30mA / DC5V (internal power supply from DC5V power of the basic unit)","Product type":"Ethernet Interface Block","Use advanced":"2000m or less can not be used in the pressurized environment to more than atmospheric pressure. There is a possibility of failure.","Shipping Weight":"1.5 Kg","lifecycle_stage":"mature","Impact resistance":"147m / s2, duration of action 11ms, X at half-sine pulse, Y, Z directions 3 times each","Relative humidity":"5 ~ 95% RH (non-condensing) ...... operation","Withstand voltage":"All terminals and between the ground terminal: AC500V 1 minute","Communication mode":"Full / half duplex","Ambient temperature":"0 ~ 55 °C ····· operation, -25 ~ 75 °C ····· during storage","Estimated Lead Time":"1 - 10 Working Days","Transmission method":"Baseband","Working environment":"Corrosive, there is no flammable gas, conductive dust (dust) that is not terribly","Insulation resistance":"All terminals and between the ground terminal: DC500V 5MO more in insulation resistance tester","Number of connections":"MELSOFT connection + MC protocol + data monitoring ? 4 connection","The maximum segment length":"100m","Direct mounting at the time Frequency":"10 ~ 57Hz: Half amplitude: 0.075mm X, Y, Z each direction 10 times (for a total of each 80 minutes)","Allowable momentary power failure time":"As well as the sequencer to be connected","The maximum number of nodes / connection":"10BASE-T: cascade up to four stages 100BASE-TX: cascade up to two-stage above is the connection possible number of stages at the time of use repeater hub. Can be connected to the number of stages at the time of switching hub used, please check with the manufacturer of the switching hub to be used.","It can be connected to the number of the basic unit":"One Ethernet adapter, as well as the communication function expansion board and other communication special adapter, and 1 channel the communication channel (CH) occupation.","Transmission Specifications Data transmission speed":"100Mbps or 10Mbps,","Vibration resistance When the DIN rail mounting Frequency":"10 ~ 57Hz: Half amplitude: 0.035mm X, Y, Z each direction 10 times (for a total of each 80 minutes)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$247.00 – $370.97","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fe6c6e1d323c67f3cf11502b600c17b5.pdf","sourceUrl":null},"ai":{"faq":[{"question":"How can I order the FX3U-ENET-ADP or check availability?","answer":"The FX3U-ENET-ADP is sourced to order against an RFQ."},{"question":"What PLCs are compatible with the FX3U-ENET-ADP?","answer":"It works with FX3U (V3.10+), FX3G (V2.00+), FX3GC (V2.00+), FX3UC (V3.10+), and FX3S (requires FX3S-CNV-ADP adapter). FX3G requires the FX3G-CNV-ADP adapter."},{"question":"What is the data rate and connection count of the FX3U-ENET-ADP?","answer":"Data rate is 100 Mbps or 10 Mbps, auto-negotiated, full or half duplex. It supports up to four simultaneous connections: MELSOFT connection, MC protocol, and data monitoring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/FX3U-ENET-ADP","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/FX3U-ENET-ADP when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}