{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"G2RV-SL700 DC24 (DC21)","brand":"Omron","brandSlug":"omron","productSlug":"G2RV-SL700-DC24-DC21","canonicalUrl":"https://aoctrl.com/omron/G2RV-SL700-DC24-DC21","factsUrl":"https://aoctrl.com/api/mcp/products/G2RV-SL700%20DC24%20(DC21)","rawCanonicalId":null},"summary":{"shortDescription":"Omron G2RV-SL700 DC24 (DC21) general purpose relay, 24 VDC coil, SPDT contact arrangement, 6 A resistive / 2.5 A inductive switching, screw terminal, -40 to 55°C operating range.","salesMarkdown":"## 6 mm-wide I/O relay with lockable test switch The Omron G2RV-SL700 DC24 (DC21) is a 6 mm-wide I/O relay that packs a lockable test switch into a slim DIN-rail footprint — a design choice that saves panel width without sacrificing the ability to manually force the output during commissioning or troubleshooting. Its 24 VDC coil and SPDT contact arrangement are standard for PLC output isolation and signal interposing, but the 6 A resistive rating at 250 VAC (1,500 VA) means it also handles moderate motor starter coil loads or solenoid valves directly, provided the inrush stays within the inductive rating of 2.5 A at 250 VAC (500 VA). ## Switching limits and minimum load The 6 A resistive rating at 250 VAC and 30 VDC defines the continuous current ceiling — above that the contact temperature rise accelerates and the mechanical life shortens. For inductive loads (contactors, small motors), the rating drops to 2.5 A at 250 VAC and 2 A at 30 VDC, reflecting the arc energy from the collapsing field. The minimum load specification of 10 mA at 5 VDC is the floor for reliable wetting — below that, oxide films on the silver-alloy contacts may not break down, causing intermittent opens in low-energy circuits like PLC dry-contact inputs. Maximum switching voltage of 400 VAC and 125 VDC sets the dielectric withstand boundary; the relay is not rated for 480 V line-to-line circuits. ## Temperature envelope and panel placement Rated for -40 to 55°C ambient, the G2RV-SL700 DC24 (DC21) can sit in an unheated enclosure or near a warm backplane, but the 55°C ceiling means derating applies if the relay is ganged in a high-density row — the self-heating from multiple coils operating simultaneously can push the internal temperature above the limit. The screw terminal simplifies field wiring with ferrule or ring terminals, common in panel builds where quick replacement without special tools is valued.","metaTitle":"Omron G2RV-SL700 DC24 (DC21) General Purpose Relay, SPDT","metaDescription":"Omron G2RV-SL700 DC24 (DC21) general purpose relay, 24 VDC coil, SPDT, 6 A resistive switching, screw terminal, -40 to 55°C. Active production, RoHS compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["General Purpose Relays"],"specifications":{"title":"G2RV-SL700 DC24 (DC21)","Terminal":"Screw","description":"G2RV|Another Omron industry first! 6 mm-wide I/O relay offers large relay style lockable test switch","Coil voltage":"24 VDC","Minimum Load":"10 mA @ 5 VDC","RoHS compliant":"Yes","lifecycle_stage":"current","Contact arrangement":"SPDT","Operating temperature":"-40 to 55°C","Max. switching current":"6 A","Max. switching voltage":"400 VAC, 125 VDC","Rated load (inductive)":"2.5 A @ 250 VAC, 2 A @ 30 VDC","Rated load (resistive)":"6 A @ 250 VAC, 6 A @ 30 VDC","Max. switching power(resistive)":"1,500 VA, 180 W","Max. switching power (inductive)":"500 VA, 60 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$24.46","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://assets.omron.com/m/674b781f60d7a701/original/G2RV-SR-G3RV-SR-Datasheet.pdf', 'path_name': '8b84fc5b273c98bb5dc9f0a2c0d91ac4.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/omron/8b84fc5b273c98bb5dc9f0a2c0d91ac4.pdf', 'status': 1}","sourceUrl":"https://automation.omron.com/en/us/products/family/g2rv"},"ai":{"faq":[{"question":"What is the closest functional second-source to G2RV-SL700 DC24 (DC21)?","answer":"The G2R-2-SNDI DC24(S) is a peer from the same G2RS family but differs in contact arrangement (DPDT vs SPDT) and terminal style (pin vs screw). The G2RV-SL700 DC24 (DC21) uses a screw terminal and a lockable test switch; the G2R-2-SNDI DC24(S) uses pin terminals and a manual push test button. They are not drop-in replacements without rewiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/omron/G2RV-SL700-DC24-DC21","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/omron/G2RV-SL700-DC24-DC21 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}