{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GC2510M6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GC2510M6","canonicalUrl":"https://aoctrl.com/schneider/GC2510M6","factsUrl":"https://aoctrl.com/api/mcp/products/GC2510M6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GC modular contactor, GC2510M6, 1-pole, 220-240 V AC 60 Hz coil, 17.5 mm width, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric GC2510M6 is a TeSys GC modular contactor, a 1-pole device with a 220...240 V AC 60 Hz control circuit. It's a clip-on DIN rail unit, 17.5 mm wide, designed for switching resistive and lightly inductive loads in control panels. Rated for utilisation categories AC-7A and AC-7B, it's suited for heating, motor control, and lighting applications. The rated breaking and making capacity is 68 A at 400 V AC for the power circuit, per IEC 61095. For a 1-pole device switching a single phase, this is the fault-clearing capability you need to check against your upstream protective device. The control circuit voltage is 220...240 V AC at 60 Hz, with a drop-out threshold of 0.2...0.75 Uc and an operational range of 0.85...1.1 Uc at 50 Hz. This means the coil will reliably pick up at 187 V and drop out below 48 V, which is important for brownout conditions or long control wiring runs. Electrical durability is rated at 100,000 cycles for both AC-7A and AC-7B categories, with mechanical durability at 1,000,000 cycles. The maximum operating rate is 300 cycles per hour at 50 °C. This is a moderate-duty contactor, not intended for high-speed cycling like a PLC output. The associated fuse rating is 25 A gL at ≤ 440 V for the power circuit. This is the maximum fuse size for short-circuit protection; the contactor itself is not a circuit breaker and relies on an upstream fuse or MCB. Heat dissipation is 1.3 W at 50/60 Hz, with 1.6 W per pole. In a crowded DIN rail enclosure, this is low enough to avoid derating concerns for adjacent devices, but still worth checking if you're packing 24 of these in a row. Clip-on mounting on a DIN rail, occupying a single 18 mm module width (17.5 mm actual). The depth is 62.5 mm, height 81 mm. This is a standard panel footprint — fits alongside miniature circuit breakers and other modular DIN rail components. Screw clamp terminals on both control and power circuits, with a tightening torque of 0.8 N.m. Power circuit accepts up to 6 mm² flexible or solid wire; control circuit accepts up to 2.5 mm². The terminal layout is straightforward for a 1-pole device. IP20 protection (fingers) per VDE 0106, IP40 in an enclosure. As an active, standard-line item, lead time is typically consistent with Schneider's distribution channel for TeSys GC components. No unusual sourcing constraints apply.","metaTitle":"Schneider TeSys GC2510M6 Modular Contactor, 1P, 220-240V AC","metaDescription":"Schneider Electric TeSys GC2510M6 modular contactor. 1-pole, 220-240V AC 60Hz coil. Rated breaking capacity 68A at 400V. Clip-on DIN rail mount. 17.5mm wide. Active production. Sou","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"62.5 mm","Width":"17.5 mm","Height":"81 mm","Current":"25 A AC-7 A 8.5 A AC-7B","Voltage":"<= 250 V AC","Application":"Heating Motor control Lighting","Coil Voltage":"220...240 V AC 60 Hz","Control Type":"Remote control","Operating Time":"10...25 ms opening 10...30 ms closing","Product Status":"Active","Temp Storage Max":"70 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"68 A at 400 V for power circuit conforming to IEC 61095","Insulation Voltage Ui":"500 V conforming to IEC 61095 500 V conforming to VDE 0110","Operating Position":"30°/vertical","Temp Operating Max":"50 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...70 °C","Control Circuit Type":"AC at 60 Hz","Utilization Category":"AC-7 A AC-7B","Electrical Life Cycles":"AC-7 A: 100000 cycles AC-7B: 100000 cycles","Mechanical Life Cycles":"1000000 cycles","Main Product Or Component Type":"Modular contactor","Ambient Air Temperature Operation":"-5...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/531247d0147e13cb8bf9635e3bb06f32.pdf","sourceUrl":"https://www.se.com/ae/en/product/GC2510M6/tesys-gc-modular-contactor-25-a-1-no-coil-220-240-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GC2510M6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GC2510M6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GC2510M6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}