{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GS2G3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GS2G3","canonicalUrl":"https://aoctrl.com/schneider/GS2G3","factsUrl":"https://aoctrl.com/api/mcp/products/GS2G3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GS series, switch-disconnector-fuse, GS2G3, 3 poles, 63 A, fuse type DIN size 000, 30 kW at 400 V.","salesMarkdown":"It's sized for DIN fuses, size 000, and rated to make and break motor and resistive loads under load. Rated operational current sits at 63 A for AC-23A and AC-23B duty across 400 V, 500 V, and 690 V, which covers the common motor-switching profiles in European and North American panel builds. Breaking capacity is 500 A at 400 V under AC-23B, so it can safely interrupt a stalled-rotor or short-circuit condition within that fault window. Rated operational power reaches 30 kW at 400 V, 40 kW at 500 V, and 55 kW at 690 V — meaning this one frame size covers a range of motor ratings depending on line voltage. The 3-pole, 3-NO contact arrangement makes it a straightforward fit for three-phase motor circuits. Mounts to a plate (not DIN rail), so plan for a drilled backplate in the enclosure. The external operating handle can be mounted on the right side or the front of the enclosure door, which gives some flexibility for panel layout. Power-circuit connections accept lugs or ring terminals from 10 to 25 mm² — common for a 63 A feed. Tightening torque is 3.2 N·m on the power terminals, which is a standard value for this wire range. The fuse cover withstands 850 °C glow-wire test per IEC 60695-2-1; the body handles 960 °C — that's fire-resistance for a panel that might see a fuse fault. The 63 A thermal current (Ith at 40 °C) sets the continuous-carry limit in free air — don't exceed that on a resistive load without derating for enclosure temperature. The AC-23B making capacity of 630 A at 400 V and breaking capacity of 500 A at 400 V tell you it can handle occasional switching of motor loads, not just infrequent isolation. Short-circuit withstand is 10.6 kA — that's the fault current the device can survive when protected by the correct upstream fuse. Rated insulation voltage is 750 V AC, impulse withstand 8 kV — that's standard for a 690 V rated switch-disconnector. No special clearance issues in a normal 400 V or 690 V panel.","metaTitle":"TeSys GS2G3 Switch-Disconnector-Fuse, 63 A, 3P, DIN","metaDescription":"TeSys GS GS2G3 switch-disconnector-fuse, 3 poles, 63 A rated operational current, IEC 60947-3, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"116.5 mm","Range":"TeSys","Width":"136 mm","title":"GS2G3","Height":"118 mm","Fuse size":"000","Fuse type":"DIN","Standards":"IEC 60947-3","description":"Switch disconnector fuse, TeSys GS, 3P, 63A, fuse type DIN, size 00C","Network type":"DC AC","Product name":"TeSys GS","Fire resistance":"850 °C fuse cover conforming to IEC 60695-2-1 960 °C body conforming to IEC 60695-2-1","Making capacity":"630 A at 400 V AC-23B","lifecycle_stage":"current","Mounting support":"Plate","Breaking capacity":"500 A at 400 V (AC-23B)","Device short name":"GS2G","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"Power circuit: 3.2 N.m","Electrical durability":"1500 cycles AC-23A 1500 cycles DC-23A 300 cycles AC-23B 300 cycles DC-23B","Mechanical durability":"10000 cycles","Connections - terminals":"Power circuit: lugs-ring terminals10...25 mm²","IP degree of protection":"IP20 conforming to IEC 60529 (with terminal cover)","Short-circuit withstand":"10.6 kA","Type of operating handle":"External right side External frontal","Product or component type":"Switch-disconnector-fuse","Protected poles description":"3t","Rated operational power in W":"30 kW at 400 V 40 kW at 500 V 55 kW at 690 V","Contacts type and composition":"3 NO","[Ui] rated insulation voltage":"750 V AC 50/60 Hz","[Ie] rated operational current":"40 A at 440 V 2 poles in series per phase DC-23A 40 A at 440 V 2 poles in series per phase DC-23B 63 A at 400 V AC-23A 63 A at 400 V AC-23B 63 A at 500 V AC-23A 63 A at 500 V AC-23B 63 A at 690 V AC-23A 63 A at 690 V AC-23B","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-20...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icm] rated short-circuit making capacity":"100 kA at 400 V with protection by gG fuses","[Ith] conventional free air thermal current":"63 A (at 40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$249.70 – $271.75","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/GS2G3/switch-disconnector-fuse-tesys-gs-3p-63a-fuse-type-din-size-00c/"},"ai":{"faq":[{"question":"What are the key ratings for the GS2G3?","answer":"Rated operational current is 63 A at 400 V AC-23B. Breaking capacity is 500 A at 400 V AC-23B. Rated power is 30 kW at 400 V, 40 kW at 500 V, 55 kW at 690 V. Short-circuit withstand is 10.6 kA."},{"question":"What standards does the GS2G3 comply with?","answer":"It complies with IEC 60947-3 for switch-disconnectors. The fuse cover meets IEC 60695-2-1 glow-wire at 850 °C; the body at 960 °C. IP20 with terminal cover."},{"question":"What is the mounting and connection style for the GS2G3?","answer":"Plate-mounted, not DIN rail. Power connections accept lugs or ring terminals 10 to 25 mm² at 3.2 N·m. External operating handle can be right-side or front-door mounted."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GS2G3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GS2G3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}