{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GS2PPB3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GS2PPB3","canonicalUrl":"https://aoctrl.com/schneider/GS2PPB3","factsUrl":"https://aoctrl.com/api/mcp/products/GS2PPB3","rawCanonicalId":null},"summary":{"shortDescription":"Switch disconnector fuse, TeSys GS, 3P, 315A, fuse type BS, size B1, B2, B3","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"149 mm","Range":"TeSys","Width":"252 mm","Height":"205 mm","Fuse size":"B3 B2 B1","Fuse type":"BS","Standards":"IEC 60947-3","Network type":"AC DC","Product name":"TeSys GS","Fire resistance":"850 °C fuse cover conforming to IEC 60695-2-1 960 °C body conforming to IEC 60695-2-1","Making capacity":"3150 A at 400 V AC-23B","lifecycle_stage":"current","Mounting support":"Plate","Breaking capacity":"2520 A at 400 V (AC-23B)","Device short name":"GS2P","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"Power circuit: 25 N.m","Electrical durability":"1000 cycles AC-23A 1000 cycles AC-23B 200 cycles DC-23A 200 cycles DC-23B","Mechanical durability":"10000 cycles","Connections - terminals":"Power circuit: bars 45 mm² Power circuit: lugs-ring terminals 185...240 mm²","IP degree of protection":"IP20 conforming to IEC 60529 (with terminal cover)","Short-circuit withstand":"40 kA","Type of operating handle":"External right side External frontal","Product or component type":"Switch-disconnector-fuse","Protected poles description":"3t","Rated operational power in W":"220 kW at 690 V 150 kW at 400 V 220 kW at 500 V 295 kW at 690 V","Contacts type and composition":"3 NO","[Ui] rated insulation voltage":"800 V AC 50/60 Hz","[Ie] rated operational current":"200 A at 440 V 2 poles in series per phase DC-23A 200 A at 440 V 2 poles in series per phase DC-23B 250 A at 690 V AC-23A 315 A at 400 V AC-23A 315 A at 400 V AC-23B 315 A at 500 V AC-23A 315 A at 500 V AC-23B 315 A at 690 V AC-23B","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-20...70 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icm] rated short-circuit making capacity":"80 kA at 400 V with protection by gG fuses","[Ith] conventional free air thermal current":"315 A (at 40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$956.56","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/GS2PPB3/switch-disconnector-fuse-tesys-gs-3p-315a-fuse-type-bs-size-b1-b2-b3/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GS2PPB3/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GS2PPB3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GS2PPB3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}