{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GS2VG3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GS2VG3","canonicalUrl":"https://aoctrl.com/schneider/GS2VG3","factsUrl":"https://aoctrl.com/api/mcp/products/GS2VG3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GS, switch-disconnector-fuse, 3P, 1250A, fuse type DIN size 4, GS2VG3.","salesMarkdown":"It takes DIN-type fuses, size 4, and is built to IEC 60947-3 for isolation and switching duty. Its headline operational current hits 630 A at 690 V in AC-23B (motor switching), and 1000 A at 440 V in the same category — that's the rating that decides fit for a motor feeder or distribution branch. The making capacity is 10 kA at 400 V AC-23B, and the breaking capacity is 8 kA at 400 V in that same duty. Rated operational power reaches 560 kW at 400 V, 560 kW at 500 V, and 475 kW at 690 V. Short-circuit withstand is 90 kA, with an impulse withstand voltage of 12 kV. This is a plate-mounted unit — not DIN-rail snap-on. It measures 442 mm wide by 355 mm high by 289 mm deep, so plan the enclosure backplate real estate accordingly. The external left-side operating handle means the door cutout and interlock placement need to account for that swing. Power circuit terminals accept bars up to 80 mm² or lugs/ring terminals for up to four 185 mm² cables. Tightening torque is a substantial 44 N·m on the power side — that's a big wrench, not a screwdriver. IP20 with the terminal cover fitted, so it's panel-internal only; no washdown exposure. The GS2VG3 carries a fire resistance rating: 850 °C on the fuse cover and 960 °C on the body, per IEC 60695-2-1. That matters for compliance dossiers in machinery CE marking or panel-build standards. Electrical durability is 500 cycles in AC-23A/B, 100 cycles in DC-23A/B; mechanical durability is 5000 cycles.","metaTitle":"Schneider Electric GS2VG3 TeSys GS Switch-Disconnector-Fuse,","metaDescription":"Schneider Electric GS2VG3 TeSys GS switch-disconnector-fuse, 3P, 1250A, fuse size 4 DIN. Rated 630 A at 690 V AC-23B, 1000 A at 440 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"289 mm","Range":"TeSys","Width":"442 mm","title":"GS2VG3","Height":"355 mm","Fuse size":"4","Fuse type":"DIN","Standards":"IEC 60947-3","description":"Switch disconnector fuse, TeSys GS, 3P, 1250A, fuse type DIN, size 4","Network type":"AC DC","Product name":"TeSys GS","Fire resistance":"850 °C fuse cover conforming to IEC 60695-2-1 960 °C body conforming to IEC 60695-2-1","Making capacity":"10000 A at 400 V AC-23B","lifecycle_stage":"current","Mounting support":"Plate","Breaking Capacity":"110 W","Breaking capacity":"8000 A at 400 V (AC-23B)","Device short name":"GS2V","Network frequency":"50/60 Hz","Poles description":"3P","Tightening torque":"Power circuit: 44 N.m","Electrical durability":"100 cycles DC-23A 100 cycles DC-23B 500 cycles AC-23A 500 cycles AC-23B","Mechanical durability":"5000 cycles","Connections - terminals":"Power circuit: bars 80 mm² Power circuit: lugs-ring terminals 4 cable(s) 185 mm²","IP degree of protection":"IP20 conforming to IEC 60529 (with terminal cover)","Short-circuit withstand":"90 kA","Type of operating handle":"External left side","Product or component type":"Switch-disconnector-fuse","Protected poles description":"3t","Rated operational power in W":"400 kW at 690 V 475 kW at 690 V 560 kW at 400 V 560 kW at 500 V","Contacts type and composition":"3 NO","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ie] rated operational current":"1000 A at 440 V 2 poles in series per phase DC-23A 1000 A at 440 V 2 poles in series per phase DC-23B 630 A at 690 V AC-23A 630 A at 690 V AC-23B 1000 A at 440 V AC-23A 1000 A at 440 V AC-23B 800 A at 500 V AC-23A 800 A at 500 V AC-23B","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-20...70 °C","[Uimp] rated impulse withstand voltage":"12 kV","[Icm] rated short-circuit making capacity":"80 kA at 400 V with protection by gG fuses","[Ith] conventional free air thermal current":"1250 A (at 40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://www.se.com/ie/en/product/download-pdf/GS2VG3?filename=Schneider+Electric_TeSys-GS_GS2VG3.pdf', 'path_name': '2392f1539c30f4ff73cf5e9ed7b8dce5.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/schneider_electric/2392f1539c30f4ff73cf5e9ed7b8dce5.pdf', 'status': 1}","sourceUrl":"https://www.se.com/nl/en/product/GS2VG3/switch-disconnector-fuse-tesys-gs-3p-1250a-fuse-type-din-size-4/"},"ai":{"faq":[{"question":"What are the key ratings for the GS2VG3?","answer":"Conventional free-air thermal current (Ith) is 1250 A at 40 °C. Operational current in AC-23B is 630 A at 690 V and 1000 A at 440 V. Breaking capacity is 8 kA at 400 V AC-23B; making capacity is 10 kA at 400 V AC-23B. Short-circuit withstand is 90 kA."},{"question":"What standard does the GS2VG3 comply with?","answer":"It is built to IEC 60947-3, the standard for switch-disconnectors and fuse-combination units."},{"question":"What is the physical size of the GS2VG3?","answer":"Width 442 mm, height 355 mm, depth 289 mm. Plate-mounted, not DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GS2VG3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GS2VG3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}