{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GT2510-VTWA","brand":"Mitsubishi Electric","brandSlug":"mitsubishi","productSlug":"GT2510-VTWA","canonicalUrl":"https://aoctrl.com/mitsubishi/GT2510-VTWA","factsUrl":"https://aoctrl.com/api/mcp/products/GT2510-VTWA","rawCanonicalId":null},"summary":{"shortDescription":"Mitsubishi GOT2000 Series GT25, GT2510-VTWA, 10.4\" TFT VGA HMI, 100-240VAC, white frame, 12 W stand-alone.","salesMarkdown":"The 100-240VAC input with a permissible instantaneous failure time of 20 ms at 100VAC or more means this HMI rides through brief line sags without a brownout reset — important on lines fed from shared transformer taps. Operating ambient temp is 0 to 55°C, storage down to -20°C; the 55°C ceiling is the panel interior temperature, not the plant floor, so factor in enclosure heating if the panel runs warm. Clamp terminals accept 0.75 to 2 mm² wire; torque the terminal screws to 0.5-0.8 N·m.","metaTitle":"Mitsubishi GT2510-VTWA GT25 HMI, 10.4\" VGA, 100-240VAC","metaDescription":"Mitsubishi GOT2000 GT2510-VTWA 10.4\" TFT VGA HMI, 100-240VAC input, white frame. Active production. Spec into your BOM line; RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["HMI Operator Interfaces"],"specifications":{"GT25":"High performance, cost efficient, mid-range model (open frame available)","title":"GT2510-VTWA","Resolution":"V = VGA (640 x 480)","Frame Color":"W = White","Product No.":"GT2510-VTWA","Screen size":"10 = 10.4\" or 10.1\"","Stand Alone":"12 W","description":"Mitsubishi GOT2000 Series Graphic Operation Terminal GT25 10.4\" Screen Size","Display Type":"T = TFT Color","Maximum Load":"34W or less","Power Supply":"A = 100 - 240VAC","Product Type":"GT25 Series HMI","Clamp Terminal":"Clamp terminals for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-N3A","Cooling Method":"Self-cooling","Inrush Current":"60A or less (2ms, ambient temperature 25°C, maximum load)","Shipping Weight":"8 Kg Kg","lifecycle_stage":"current","Noise Resistance":"Noise voltage 1500Vp-p, noise width 1µs by noise simulator with noise frequency 25 to 60Hz","Pollution Degree":"2 or less","Withstand Voltage":"1500VAC for 1 minute between power supply terminal and ground","Operating Altitude":"2000m (6562 ft) or less","Estimated Lead Time":"Usually ships in 1-10 working days.","Applicable Wire Size":"0.75 to 2 [mm²]","Operating Atmosphere":"No greasy fumes, corrosive gas, flammable gas, excessive conductive dust, and direct sunlight (as well as at storage)","Overvoltage Category":"II or less","Installation Location":"Inside control panel","Insulation Resistance":"10MO or higher with an insulation resistance tester (500VDC between power supply terminal and ground)","Operating Ambient Temp.":"0 to 55°C (*2)","Storage Ambient Humidity":"10 to 90%RH, no condensation","Input Power Supply Voltage":"100 to 240VAC (+10%, -15%)","Operating Ambient Humidity":"10 to 90%RH, no condensation","Stand Alone w/Backlight Off":"7 W","Storage Ambient Temperature":"-20°C to 60°C","External Dimensions ( W x H x D )":"30.3 cm x 21.8 cm x 5.2 cm","Weight Excludes Mounting Brackets":"2.1 Kg","Permissible Instantaneous Failure Time":"Within 20ms (100VAC or more)","Tightening Torque (Terminal Block’s Terminal Screws)":"0.5 to 0.8 [N.m]"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,809.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/906e515af78451c8b3f0148317a0bed8.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What are the key power ratings for this HMI?","answer":"Input power supply is 100-240VAC (+10%, -15%). Stand-alone consumption is 12 W; with backlight off it draws 7 W. Maximum load (including expansion units) is 34 W or less. Inrush current is 60 A or less for 2 ms at 25°C."},{"question":"What environmental conditions does it tolerate?","answer":"Operating ambient temperature is 0 to 55°C; storage -20°C to 60°C. Humidity 10-90% RH non-condensing. Pollution degree 2, overvoltage category II. Rated for installation inside a control panel, free of greasy fumes, corrosive gas, flammable gas, and excessive conductive dust."},{"question":"Will the GT2510-VTWA drop into a panel specified around an FX5U-32MT/DS-TS CPU module?","answer":"No — the FX5U-32MT/DS-TS is a PLC CPU module, not an HMI. They serve different functions and have different mounting footprints, power supplies, and wiring. The GT2510-VTWA connects to the FX5U via Ethernet or serial as a separate panel-mount device, not as a direct replacement."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/mitsubishi/GT2510-VTWA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/mitsubishi/GT2510-VTWA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}