{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2DM102F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2DM102F7","canonicalUrl":"https://aoctrl.com/schneider/GV2DM102F7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2DM102F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2DM102F7 DOL combination starter, non-reversing, 3-pole, thermal protection 0.16…0.25 A, 110 V AC coil, 50 kA breaking capacity at 400/415 V AC.","salesMarkdown":"The GV2DM102F7 is a non-reversing DOL combination starter from the TeSys Deca family, integrating a GV2ME motor circuit breaker and a 3-pole contactor in one block with a GV2AF3 auxiliary contact block. Its thermal protection adjustment range of 0.16…0.25 A makes it suited for very small motor loads — think fractional-horsepower pumps, small fans, or conveyor drives below 0.06 kW at 400/415 V AC. Rated breaking capacity hits 50 kA at 400/415 V (IEC 60947-4-1), so it can clear a bolted fault on a 50 kA available fault-current bus without upstream coordination worries — Type 1 coordination means the starter may need replacement after a fault, but the downstream motor stays protected. The magnetic tripping threshold is fixed at 2.4 A, which triggers instantaneously on short-circuit; the thermal bimetallic element handles the 0.16…0.25 A overload band. That narrow window means this part is not a general-purpose breaker — it is sized specifically for the motor's full-load current. The 0.06 kW motor power rating at 400/415 V AC (50/60 Hz) and 0.06 kW at 440 V AC is the headline selection parameter — this starter is for sub-0.1 kW motors only. The 110 V AC coil voltage means the control circuit must supply 110 V AC; verify your panel's control transformer voltage before specifying. Dimensions (176.4 mm height, 45 mm width, 99.6 mm depth) fit a standard DIN-rail footprint. The 45 mm width is typical for a 3-pole motor starter in the TeSys Deca range.","metaTitle":"TeSys Deca GV2DM102F7 Motor Starter, 0.16…0.25 A, 110 V AC,","metaDescription":"GV2DM102F7 DOL combination starter, 0.16…0.25 A thermal range, 50 kA breaking capacity at 400/415 V. Obsolete — sourced to order against RFQ. TeSys Deca series.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"99.6 mm","Width":"45 mm","Height":"176.4 mm","Motor power kW":"0.06 kW at 400/415 V AC 50/60 Hz 0.06 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Range of product":"TeSys Deca","Coordination type":"Type 1","Device short name":"GV2DM","Poles description":"3P","Device composition":"1 combination block GV2AF3 1 3-pole contactor 1 motor circuit breaker type GV2ME","Motor starter type":"Non reversing","Utilisation category":"AC-3","Rated breaking capacity":"Iq 50 kA at 400/415 V conforming to IEC 60947-4-1 Iq 50 kA at 440 V conforming to IEC 60947-4-1 Iq 50 kA at 500 V conforming to IEC 60947-4-1","Magnetic tripping current":"2.4 A","Product or component type":"Motor starter","Thermal protection adjustment range":"0.16...0.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/nl/en/product/GV2DM102F7/dol-combination-starter-tesys-deca-0-16-0-25-a-110-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2DM102F7/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy GV2DM102F7 and how do I get a price?","answer":"The GV2DM102F7 is sourced through independent distribution channels — new-old-stock or verified surplus. Submit an RFQ; availability and current pricing are confirmed at quote time. No stock count or price figure is published here."},{"question":"What is the thermal protection adjustment range of GV2DM102F7?","answer":"The thermal protection adjustment range is 0.16…0.25 A, set via the bimetallic overload relay integrated into the motor circuit breaker section."},{"question":"What breaking capacity does GV2DM102F7 offer?","answer":"Rated breaking capacity is 50 kA at 400/415 V AC and at 440 V AC, per IEC 60947-4-1. This covers most industrial distribution panels with high available fault current."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2DM102F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2DM102F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}