{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2DM116B7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2DM116B7","canonicalUrl":"https://aoctrl.com/schneider/GV2DM116B7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2DM116B7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric GV2DM116B7, manual motor starter, GV2 series, 9/14 A rated current, 2.2 kW at 230V AC to 5.5 kW at 500-690V AC3, 25 A thermal current, 690 V insulation voltage.","salesMarkdown":"The GV2DM116B7 is a manual motor starter from Schneider's GV2 series, sized for motors drawing 9 A nominal with a 14 A magnetic trip threshold — the 9/14 A pair means the thermal overload element is set for 9 A continuous, and the short-circuit release triggers at 14 A. AC3 power ratings of 2.2 kW at 230 V, 4 kW at 400 V, and 5.5 kW at 500-690 V cover standard three-phase induction motors across European and North American line voltages; the 50/60 Hz frequency acceptance means it works on either supply without derating. The 25 A thermal current (Ith) is the unrestricted current the main poles can carry in free air — useful when the starter feeds a distribution block rather than directly into a motor. Snap-on DIN rail mounting for 35 mm symmetrical rail per EN 60715. The GV2 body width is 45 mm — one standard modular unit — so it occupies a single 45 mm slot in the enclosure. Coil supply is 24 V AC; the control circuit draws from a separate 24 V AC source, not the motor power. For a panel-builder wiring the line: incoming power lands on the top terminals, motor leads on the bottom, auxiliary contact block clips onto the side for status feedback to the PLC.","metaTitle":"Schneider GV2DM116B7 Motor Starter, 9/14A, 2.2-5.5 kW AC3","metaDescription":"Schneider GV2DM116B7 motor starter, rated 9/14 A, 2.2 kW at 230V AC to 5.5 kW at 500-690V AC3. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Type":"Motor Starter","Model":"GV2DM116B7","title":"GV2DM116B7","Torque":"15 lb.in","Weight":"0,73 kg","Condition":"New","Frequency":"50/60Hz","Shelf No.":"250132","Power (AC3)":"2.2 kW at 230V AC, 4 kW at 400V AC, 5.5 kW at 500-690V AC","description":"SCHNEIDER GV2DM116B7 MOTOR STARTER","Rated Current":"9 / 14A","Rated Voltage":"24V AC","Thermal Current":"25A","Type of Product":"Motor Starter","lifecycle_stage":"current","Rated Insulation Voltage (Ui)":"690V","Rated Impulse-Withstand Voltage (Uimp)":"6KV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/833641c3fe8988864268f0510edd59d3.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What are the AC3 power ratings for GV2DM116B7?","answer":"The GV2DM116B7 is rated 2.2 kW at 230 V AC, 4 kW at 400 V AC, and 5.5 kW at 500-690 V AC under AC3 duty — covering standard three-phase induction motor loads across common supply voltages."},{"question":"Where can I buy GV2DM116B7?","answer":"This part is sourced to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2DM116B7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2DM116B7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}