{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2L10","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2L10","canonicalUrl":"https://aoctrl.com/schneider/GV2L10","factsUrl":"https://aoctrl.com/api/mcp/products/GV2L10","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys GV2L10 motor circuit breaker, 3-pole, 6.3 A, magnetic trip 91 A, 100 kA breaking capacity at 400 V AC, dark grey, IP20, DIN rail mount.","salesMarkdown":"The TeSys GV2L10 is a 3-pole motor circuit breaker from Schneider's TeSys Deca range, sized for motor protection at 6.3 A rated current. Its magnetic-only trip unit picks up at 91 A, providing fast short-circuit interruption while leaving thermal overload protection to an external relay. The rotary handle allows manual switching, and the device is marked suitable for isolation per IEC 60947-1. Magnetic trip at 91 A clears shorts quickly; pair with a separate overload relay since there is no thermal element. Insulation rated 690 V. The magnetic-only trip makes this a compact option for motor starters where the overload relay handles thermal protection separately. The electrical endurance is rated at 100,000 cycles under AC-3 duty at rated current, matching typical contactor life in motor start applications. Screw-clamp power terminals accept 1–6 mm² solid or stranded wire (1–4 mm² with ferrule). Tighten to 1.7 N·m. The housing is dark grey with IP20 protection and IK04 impact resistance. Depth is 97 mm, width 45 mm — fits standard distribution boards with room for auxiliary contacts on the side. The breaker can be mounted horizontally or vertically. Fire resistance tested at 960 °C per IEC 60695-2-11.","metaTitle":"TeSys GV2L10 Motor Circuit Breaker, 6.3 A, 100 kA","metaDescription":"Schneider TeSys GV2L10 motor circuit breaker, 6.3 A rated current, magnetic trip at 91 A, 100 kA breaking capacity at 400 V AC. 3-pole, DIN rail mount, IP20, current production. So","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"3.8 in (97 mm)","Range":"TeSys Deca","Width":"1.8 in (45 mm)","Height":"3.5 in (89 mm)","Category":"US10I1122367","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with 2 x M4 screws)","Control Type":"Rotary handle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"2.2 kW 400/415 V AC 50/60 Hz 3 kW 500 V AC 50/60 Hz 4 kW 690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 4 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Device short name":"GV2L","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Tightening torque":"15.05 lbf.in (1.7 N.m) screw clamp terminal","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"6.3 A","Operating altitude":"<= 6561.68 ft (2000 m)","Trip unit technology":"Magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1 AC-3e IEC 60947-4-1","Electrical durability":"100000 cycles AC-3 415 V In 100000 cycles AC-3e 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks 30 Gn for 11 ms Vibrations 5 Gn, 5...150 Hz","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit screw clamp terminal 2 0.002...0.009 in² (1...6 mm²)solid Power circuit screw clamp terminal 2 0.002...0.009 in² (1.5...6 mm²)flexible without cable end Power circuit screw clamp terminal 2 0.002...0.006 in² (1...4 mm²)flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"91 A","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"1.8 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"6.3 A IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 690 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$30.56","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/05bb2e9516a159b1fafdf45bdf78de62.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2L10/alternatives.json"},"ai":{"faq":[{"question":"What is the color of the GV2L10?","answer":"The housing color is dark grey."},{"question":"What is the depth of the GV2L10?","answer":"The depth is 97 mm (3.8 in)."},{"question":"What compliance standards does the GV2L10 meet?","answer":"It meets EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40 Annex JJ. It also has IP20 and IK04 protection ratings and fire resistance at 960 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2L10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2L10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}