{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2LC0206","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2LC0206","canonicalUrl":"https://aoctrl.com/schneider/GV2LC0206","factsUrl":"https://aoctrl.com/api/mcp/products/GV2LC0206","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2LC, enclosed DOL starter, 1.6 A thermal protection, 100 kA breaking capacity at 400 V, IP54, obsolete.","salesMarkdown":"The Schneider Electric TeSys GV2LC0206 is an enclosed direct-on-line (DOL) motor starter with a built-in circuit breaker, rated for a thermal protection adjustment range of 1.6 A. It is a non-reversing, 3-pole unit using magnetic trip technology, with a magnetic tripping limit of 13 x In ±20%. The enclosure is polycarbonate with an IP54 rating per IEC 60529, making it suitable for environments where dust and water splash are present, such as light industrial or washdown areas. Breaking capacity is 100 kA Icu at 220–230 V, 400–415 V, 440 V, and 500 V per IEC 60947-2. Rated operational voltage is 690 V. Cable entry accommodates 2 x 25 mm² ISO at top and bottom, and 2 x 20 mm² ISO at top and bottom, giving flexibility for panel gland-plate layout. The rotary handle (black) can be locked in the OFF position with 1 to 3 padlocks (Ø 8 mm) for lockout/tagout procedures. ## Integration notes Dimensions are 166 mm height, 88 mm width, and 173 mm depth. The IP54 polycarbonate enclosure is self-contained — no additional panel cutout is needed; it mounts directly to a machine frame or wall via the enclosure's integral fixing points. Cable entry is via ISO metric knockouts, so plan your gland selection accordingly (2 x 25 mm² top/bottom, 2 x 20 mm² top/bottom). The rotary handle protrudes from the enclosure front; ensure clearance for the handle swing and for padlock application in the OFF position. The unit is a combined circuit breaker and starter in one package — no separate overload relay is needed, which simplifies wiring but means the thermal setting (1.6 A) is fixed by the unit's adjustment range. If your motor FLA is outside that range, this unit will not provide proper overload protection.","metaTitle":"TeSys GV2LC0206 Enclosed DOL Starter, 1.6 A, 100 kA","metaDescription":"Schneider TeSys GV2LC0206 enclosed DOL starter, 1.6 A thermal setting, 100 kA breaking capacity at 400 V. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"173 mm","Width":"88 mm","Height":"166 mm","Standards":"EN 60947 IEC 60439-1 VDE 0660-102 IEC 60947-4","Cable Entry":"2 x 25 mm ISO at top 2 x 20 mm ISO at bottom 2 x 20 mm ISO at top 2 x 25 mm ISO at bottom","Control type":"Rotary handle black","lifecycle_stage":"current","Range of product":"TeSys","Breaking capacity":"100 kA Icu at 220...230 V conforming to IEC 60947-2 100 kA Icu at 400...415 V conforming to IEC 60947-2 100 kA Icu at 440 V conforming to IEC 60947-2 100 kA Icu at 500 V conforming to IEC 60947-2","Device short name":"GV2LC","Poles description":"3P","Enclosure material":"Polycarbonate","Motor starter type":"Non reversing","Trip unit technology":"Magnetic","IP degree of protection":"IP54 conforming to IEC 60529","Magnetic tripping limit":"13 x In +/- 20 %","Motor starter composition":"With circuit breaker","Product or component type":"Enclosed DOL starter","Locking options description":"1 to 3 padlocks Ø 8 Padlock in OFF position","[Ue] rated operational voltage":"690 V","Thermal protection adjustment range":"1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8274680bc0b4baf29a5aec8b437e73af.pdf","sourceUrl":"https://www.se.com/ie/en/product/GV2LC0206/enclosed-dol-starter-tesys-gv2lc-1-6-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2LC0206/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the GV2LC0206?","answer":"It has a breaking capacity of 100 kA Icu at 220–230 V, 400–415 V, 440 V, and 500 V, per IEC 60947-2. This high rating means it can handle severe fault currents without upstream devices needing to intervene."},{"question":"What is the thermal protection setting range?","answer":"The thermal protection adjustment range is 1.6 A. This is a fixed setting for this unit — it protects a motor with a full-load current up to that value."},{"question":"What standards does the GV2LC0206 comply with?","answer":"It complies with EN 60947, IEC 60439-1, VDE 0660-102, and IEC 60947-4. These cover motor starter and distribution applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2LC0206","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2LC0206 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}