{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2LC0207R","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2LC0207R","canonicalUrl":"https://aoctrl.com/schneider/GV2LC0207R","factsUrl":"https://aoctrl.com/api/mcp/products/GV2LC0207R","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-LC enclosed DOL starter, GV2LC0207R, 2.5 A thermal protection, 3-pole, IP54, 100 kA breaking capacity.","salesMarkdown":"The Schneider Electric TeSys GV2LC0207R is an enclosed direct-on-line (DOL) starter — a self-contained unit combining a circuit breaker and a magnetic trip in a single polycarbonate enclosure, rated for a 2.5 A thermal protection setting. This is the part you spec when you need a compact, IP54-rated motor starter for a small pump, fan, or conveyor that doesn't justify a separate breaker-and-contactor assembly. The IP54 rating means it's sealed against dust ingress and splashing water — suitable for installation in washdown areas or outdoor enclosures where you don't want a separate cabinet. The headline number is the 2.5 A thermal protection adjustment range — that's the motor full-load current it's designed to protect. If your motor draws 2.3 A FLA, this starter will trip on overload at the right threshold; if your motor draws 3 A, you need the next size up. The magnetic trip (short-circuit protection) is fixed and coordinated with the thermal element, so you don't set it separately. Breaking capacity is 100 kA Icu at 400…415 V (per IEC 60947-2). In practice, unless your panel's prospective fault current is above that level, you don't need an upstream current-limiting fuse. Rated operational voltage goes up to 690 V, so it's fine on 400 V three-phase systems common in European and Asian industrial plants. The polycarbonate enclosure is rated IP54, so it handles dust and hose-down, but it's not submersible — keep it out of standing water. Dimensions are 166 mm high × 88 mm wide × 173 mm deep — it's a compact brick that mounts directly to a backplate or inside a small enclosure. Cable entry is provided top and bottom: 2 × 20 mm ISO and 2 × 25 mm ISO knockouts at both ends, so you can route incoming supply and motor leads without drilling. The red rotary handle protrudes from the front; the enclosure is designed for surface mounting, not DIN rail. Standards compliance includes IEC 60439-1, EN 60947, IEC 60947-4, and VDE 0660-102 — covers the main European low-voltage switchgear and motor-starter standards. For UL/CSA compliance, verify the specific listing for your jurisdiction; the evidence doesn't carry those marks.","metaTitle":"Schneider TeSys GV2LC0207R Enclosed DOL Starter, 2.5 A","metaDescription":"Schneider TeSys GV2LC0207R enclosed DOL starter, 2.5 A thermal protection, IP54, 100 kA breaking capacity. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"173 mm","Width":"88 mm","title":"GV2LC0207R","Height":"166 mm","Standards":"IEC 60439-1 EN 60947 IEC 60947-4 VDE 0660-102","Cable Entry":"2 x 20 mm ISO at bottom 2 x 25 mm ISO at top 2 x 25 mm ISO at bottom 2 x 20 mm ISO at top","description":"enclosed DOL starter TeSys - GV2-LC - 2.5 A","Control type":"Rotary handle red","lifecycle_stage":"current","Range of product":"TeSys","Breaking capacity":"100 kA Icu at 220...230 V conforming to IEC 60947-2 100 kA Icu at 400...415 V conforming to IEC 60947-2 100 kA Icu at 440 V conforming to IEC 60947-2 100 kA Icu at 500 V conforming to IEC 60947-2","Device short name":"GV2LC","Poles description":"3P","Enclosure material":"Polycarbonate","Motor starter type":"Non reversing","Trip unit technology":"Magnetic","IP degree of protection":"IP54 conforming to IEC 60529","Motor starter composition":"With circuit breaker","Product or component type":"Enclosed DOL starter","Locking options description":"1 to 3 padlocks Ø 8 Padlock in OFF position","[Ue] rated operational voltage":"690 V","Thermal protection adjustment range":"2.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4d4a0c482ccbd0660828630272d15668.pdf","sourceUrl":"https://www.se.com/be/en/product/GV2LC0207R/enclosed-dol-starter-tesys-gv2lc-2-5-a/"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The thermal protection adjustment range is 2.5 A — that's the motor FLA it protects. Breaking capacity is 100 kA Icu at 400…415 V. Rated operational voltage is 690 V. Enclosure is IP54."},{"question":"What standards does this starter comply with?","answer":"It complies with IEC 60439-1, EN 60947, IEC 60947-4, and VDE 0660-102."},{"question":"What are the mounting dimensions and cable entry?","answer":"Dimensions are 166 mm high × 88 mm wide × 173 mm deep. Cable knockouts: 2 × 20 mm ISO and 2 × 25 mm ISO at both top and bottom."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2LC0207R","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2LC0207R when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}