{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2LC0214","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2LC0214","canonicalUrl":"https://aoctrl.com/schneider/GV2LC0214","factsUrl":"https://aoctrl.com/api/mcp/products/GV2LC0214","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2LC0214, enclosed DOL starter, 10 A thermal protection adjustment range, IP54 polycarbonate enclosure, 3-pole non-reversing with magnetic trip.","salesMarkdown":"The Schneider Electric GV2LC0214 is an enclosed direct-on-line (DOL) starter from the TeSys range, combining a circuit breaker and magnetic trip unit in one polycarbonate enclosure. It's rated for a thermal protection adjustment range of 10 A, meaning it's sized for a motor drawing that full-load current — set the dial to match the nameplate, and the magnetic trip hits at 13 x In (±20%) for short-circuit protection. The IP54 rating (per IEC 60529) means the enclosure is dust-protected and splash-proof — not submersible, but fine for washdown areas, pump stations, or outdoor cabinets where hose spray is a risk. The polycarbonate shell won't corrode like painted steel in a wet well atmosphere, though I'd still keep it out of direct H2S off-gassing if the concentration is heavy. ## Breaking capacity — what it handles Breaking capacity varies with voltage: 100 kA Icu at 220–230 V and 400–415 V, 20 kA at 440 V, and 10 kA at 500 V, all conforming to IEC 60947-2. At 400 V three-phase — common for industrial motor circuits — the 100 kA figure gives you serious fault-clearing headroom, enough for most distribution panels without needing upstream current-limiting fuses. ## Enclosure and integration details The enclosure dimensions are 173 mm deep, 88 mm wide, and 166 mm high. Cable entries are pre-cut for ISO knockouts: two 20 mm at top and bottom, plus two 25 mm at top and bottom — enough for incoming supply and motor leads through separate glands. The black rotary handle extends through the cover for manual ON/OFF and can be padlocked in the OFF position with up to three 8 mm padlocks for lockout/tagout.","metaTitle":"Schneider Electric GV2LC0214 TeSys Enclosed DOL Starter, 10","metaDescription":"GV2LC0214 enclosed DOL starter from Schneider Electric TeSys range. 10 A thermal protection, magnetic trip, IP54 polycarbonate enclosure. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"173 mm","Width":"88 mm","title":"GV2LC0214","Height":"166 mm","Standards":"VDE 0660-102 IEC 60947-4 IEC 60439-1 EN 60947","Cable Entry":"2 x 20 mm ISO at bottom 2 x 20 mm ISO at top 2 x 25 mm ISO at top 2 x 25 mm ISO at bottom","description":"enclosed DOL starter TeSys - GV2-LC - 10 A","Control type":"Rotary handle black","lifecycle_stage":"current","Range of product":"TeSys","Breaking capacity":"10 kA Icu at 500 V conforming to IEC 60947-2 100 kA Icu at 220...230 V conforming to IEC 60947-2 100 kA Icu at 400...415 V conforming to IEC 60947-2 20 kA Icu at 440 V conforming to IEC 60947-2","Device short name":"GV2LC","Poles description":"3P","Enclosure material":"Polycarbonate","Motor starter type":"Non reversing","Trip unit technology":"Magnetic","IP degree of protection":"IP54 conforming to IEC 60529","Magnetic tripping limit":"13 x In +/- 20 %","Motor starter composition":"With circuit breaker","Product or component type":"Enclosed DOL starter","Locking options description":"Padlock in OFF position 1 to 3 padlocks Ø 8","[Ue] rated operational voltage":"690 V","Thermal protection adjustment range":"10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6d4380cb855b498240d73f112c99fddb.pdf","sourceUrl":"https://www.se.com/ie/en/product/GV2LC0214/enclosed-dol-starter-tesys-gv2lc-10-a/"},"ai":{"faq":[{"question":"What are the key ratings for the GV2LC0214?","answer":"Thermal protection adjustment range is 10 A, with a magnetic trip limit of 13 x In (±20%). Breaking capacity reaches 100 kA Icu at 400–415 V (IEC 60947-2). The enclosure is rated IP54 and measures 173 mm deep by 88 mm wide by 166 mm high."},{"question":"What compliance standards does the GV2LC0214 meet?","answer":"It conforms to VDE 0660-102, IEC 60947-4, IEC 60439-1, and EN 60947. The IP54 rating is per IEC 60529, and breaking capacity is certified to IEC 60947-2."},{"question":"What cable entries does the enclosure have?","answer":"The polycarbonate enclosure has four ISO knockouts: two 20 mm and two 25 mm at both top and bottom, giving flexibility for cable gland sizes on the supply and motor side."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2LC0214","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2LC0214 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}