{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2LE04","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2LE04","canonicalUrl":"https://aoctrl.com/schneider/GV2LE04","factsUrl":"https://aoctrl.com/api/mcp/products/GV2LE04","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 GV2LE04 motor circuit breaker, 3-pole, 0.63 A rated current, magnetic trip 9.3 A, 100 kA breaking capacity, dark grey, 45 mm wide.","salesMarkdown":"The GV2LE04 is a 3-pole motor circuit breaker from the TeSys GV2 range, rated at 0.63 A continuous. It uses magnetic-only trip technology with a fixed magnetic tripping current of 9.3 A — designed for motor protection where short-circuit clearance is needed without the thermal overload curve. Breaking capacity is 100 kA Icu across 230–690 V AC 50/60 Hz, giving it headroom for high-fault panels. Certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40:Annex JJ. Fire resistance rated at 960 °C per IEC 60695-2-11. IP20 housing. ## Panel integration — mounting and wiring Mounts in horizontal or vertical orientation. Screw clamp terminals accept 1–6 mm² solid or 1.5–6 mm² flexible without cable end, or 1–4 mm² flexible with cable end. Tighten to 1.7 N·m. Depth: 3.09 in (78.5 mm); width: 1.8 in (45 mm); height: 3.5 in (89 mm). Climate withstand per IACS.","metaTitle":"GV2LE04 TeSys GV2 Motor Circuit Breaker, 0.63 A","metaDescription":"Schneider GV2LE04 TeSys GV2 motor circuit breaker. 0.63 A rated, 3-pole, magnetic trip 9.3 A, 100 kA breaking capacity. Current lifecycle. Sourced to order. UL/CSA/IEC.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"3.09 in (78.5 mm)","Range":"TeSys Deca","Width":"1.8 in (45 mm)","Height":"3.5 in (89 mm)","Category":"US1CP1018402","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with adaptor plate)","Control Type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.12 kW 400/415 V AC 50/60 Hz 0.18 kW 400/415 V AC 50/60 Hz 0.37 kW 690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Device short name":"GV2LE","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Tightening torque":"15.05 lbf.in (1.7 N.m) screw clamp terminal","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"0.63 A","Operating altitude":"<= 6561.68 ft (2000 m)","Trip unit technology":"Magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1 AC-3e IEC 60947-4-1","Electrical durability":"100000 cycles AC-3 415 V In 100000 cycles AC-3e 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks 30 Gn for 11 ms Vibrations 5 Gn, 5...150 Hz","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit screw clamp terminal 2 0.002...0.009 in² (1...6 mm²)solid Power circuit screw clamp terminal 2 0.002...0.009 in² (1.5...6 mm²)flexible without cable end Power circuit screw clamp terminal 2 0.002...0.006 in² (1...4 mm²)flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"9.3 A","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"1.8 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"0.63 A IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 690 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$295.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c027c092fd35b072e619993e6d0ac0f1.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2LE04/alternatives.json"},"ai":{"faq":[{"question":"What is the GV2LE04's color?","answer":"The housing is dark grey."},{"question":"What is the GV2LE04's depth?","answer":"The depth is 3.09 in (78.5 mm)."},{"question":"What compliance documentation does Schneider provide for the GV2LE04?","answer":"The part is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40:Annex JJ. Fire resistance is rated at 960 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2LE04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2LE04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}