{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2LE22TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2LE22TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2LE22TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2LE22TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2LE22TQ, motor circuit breaker, 3P, 25 A In, magnetic trip, 9-18.5 kW motor protection, DIN rail mount.","salesMarkdown":"It's a 3-pole device with a rated current of 25 A and magnetic trip technology, meaning it uses a fixed magnetic trip coil for short-circuit protection rather than a thermal bimetallic strip. This breaker is rated for motor protection duty in utilisation category AC-3 (and AC-3e) per IEC 60947-4-1, which covers starting and disconnecting squirrel-cage motors during running. The motor power ratings span 9 kW at 400/415 V up to 18.5 kW at 690 V, so it covers a useful range of small to medium induction motors on 400 V and 690 V line supplies. The breaking capacity (Icu) varies significantly with voltage: 50 kA at 230/240 V, 15 kA at 400/415 V, 6 kA at 440 V, 4 kA at 500 V, and 3 kA at 690 V. At the common 400 V industrial supply, 15 kA is adequate for most downstream distribution panels but may need upstream current-limiting fuses or a higher-rated breaker if the prospective fault current exceeds that level. For selective coordination, you'd need a Category B breaker. This is a standard distinction for motor circuit breakers — they clear fast, which is what motor protection needs, but it means the upstream breaker must be sized to handle the full fault current. The 45 mm width (3 module spaces) fits standard enclosure rail. Horizontal or vertical orientation is acceptable, which helps when laying out a dense panel. Power connections use screw clamp terminals accepting 1 to 6 mm² solid or 1.5 to 6 mm² flexible cable (without ferrule), or 1 to 4 mm² with ferrule. Tightening torque is 1.7 N·m. As a current-production part, lead times are standard for the TeSys Deca family. If you need a set of 24 (the quantity per set), that's the standard packaging unit — order one line item. Certified to EN/IEC 60947-2 (circuit-breakers), EN/IEC 60947-4-1 (contactors and motor-starters), UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40 Annex JJ (for heat pump applications). The UL and CSA marks cover North American installations. It's also suitable for isolation per IEC 60947-1, meaning it can be used as a visible-break disconnect when locked off. Climatic withstand conforms to IACS (marine/offshore environmental testing). Fire resistance is 960 °C per IEC 60695-2-11. Operating altitude is limited to 2000 m without derating.","metaTitle":"Schneider GV2LE22TQ TeSys Deca Motor Circuit Breaker, 25 A","metaDescription":"Schneider GV2LE22TQ TeSys Deca motor circuit breaker, 25 A rated current, 9-18.5 kW motor protection. EN/IEC/UL/CSA certified. Active production. DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Toggle","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"9 kW at 400/415 V AC 50/60 Hz 11 kW at 400/415 V AC 50/60 Hz 11 kW at 500 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 18.5 kW at 690 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2LE","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"25 A","Trip unit technology":"Magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"388.3 A","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"1.8 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"25 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 40 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d8743391e13bc332de837fd9e5fddd7c.pdf","sourceUrl":"https://www.se.com/vn/en/product/GV2LE22TQ/motor-circuit-breakertesys-deca-frame-23p25amagnetictoggle-controlscrew-clamp-terminalsbulk-qty/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2LE22TQ/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to GV2LE22TQ in the TeSys Deca family?","answer":"Within the GV2LE series, the closest alternative would be a different current rating — for example, the GV2LE20 (18 A) or GV2LE32 (32 A) — but the GV2LE22TQ at 25 A is a standard rating. There is no pin-compatible alternative with the same 25 A rating; you'd need to change the trip unit rating if you need a different motor protection curve."},{"question":"What is the depth of GV2LE22TQ?","answer":"The depth is 78.5 mm. Width is 45 mm (3 module spaces), height is 89 mm."},{"question":"What compliance documentation is available for GV2LE22TQ?","answer":"The part carries EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40 Annex JJ certifications. It also meets IACS climatic withstand and IEC 60695-2-11 fire resistance at 960 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2LE22TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2LE22TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}