{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME01AP","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME01AP","canonicalUrl":"https://aoctrl.com/schneider/GV2ME01AP","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME01AP","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2ME01AP motor circuit breaker, 3-pole, 0.16 A rated current, thermal-magnetic trip, 100 kA breaking capacity, IP20, DIN-rail mount.","salesMarkdown":"Its rated current is 0.16 A, with a thermal protection adjustment range of 0.1...0.16 A and a magnetic tripping current of 1.93 A. This means it's sized for the smallest fractional-horsepower motors — think tiny fans, pumps, or conveyor drives drawing under 0.2 A full-load. The 45 mm width means it takes a single modular space on the rail. Accepts power wiring up to 6 mm² solid or 4 mm² flexible with ferrule, torqued to 1.7 N·m. Horizontal or vertical mounting position, no derating needed. Listed to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (motor-starter standard), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1. That covers the major North American and international regulatory jurisdictions. Also carries a 960 °C glow-wire fire resistance rating per IEC 60695-2-11. Phase-failure sensitive per IEC 60947-4-1, and suitable for isolation per IEC 60947-1.","metaTitle":"Schneider TeSys GV2ME01AP Motor Circuit Breaker, 0.16 A, 100","metaDescription":"Schneider Electric TeSys GV2ME01AP motor circuit breaker, 0.16 A rated current, thermal-magnetic trip, 100 kA breaking capacity at 400 V. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 230/240 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.16 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"1.93 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.1...0.16 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.16 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50 Hz conforming to IEC 60947-2 100 % at 440 V AC 50 Hz conforming to IEC 60947-2 100 % at 500 V AC 50 Hz conforming to IEC 60947-2 100 % at 690 V AC 50 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5f12e7f01e0314e9bb6c2a202d208d6a.pdf","sourceUrl":"https://www.se.com/mk/en/product/GV2ME01AP/motor-circuit-breaker-tesys-deca-3p-0-1-to-0-16a-thermal-magnetic-screw-clamp-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME01AP/alternatives.json"},"ai":{"faq":[{"question":"What is GV2ME01AP's rated current and what size motor does it protect?","answer":"Rated current is 0.16 A, with a thermal adjustment range of 0.1...0.16 A. The magnetic trip is fixed at 1.93 A. This protects the smallest fractional-horsepower motors — typically under 0.05 kW at 400 V."},{"question":"What breaking capacity does GV2ME01AP have?","answer":"100 kA Icu at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC, 50 Hz, per IEC 60947-2. That's a high interrupting rating for a breaker this small — it can handle high fault current without cascading upstream."},{"question":"What compliance documentation does this brand provide for GV2ME01AP?","answer":"The part carries UL 60947-4-1, CSA C22.2 No 60947-4-1, and EN/IEC 60947-2 and 60947-4-1 certifications. It also meets IEC 60695-2-11 glow-wire at 960 °C. RoHS and REACH compliance is standard for the TeSys range, though specific declarations are issued per shipment."},{"question":"What is GV2ME01AP's listed depth?","answer":"78.5 mm depth, 89 mm height, 45 mm width. Fits a standard 35 mm DIN-rail footprint."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME01AP","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME01AP when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}