{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME01TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME01TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2ME01TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME01TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2ME01TQ motor circuit breaker, 3-pole, 0.16 A, thermal-magnetic, 100 kA breaking capacity, IP20, DIN rail mount.","salesMarkdown":"The magnetic trip is set at 1.93 A, so it clears short-circuit faults fast. It's also phase-failure sensitive per IEC 60947-4-1, meaning it'll trip if one phase drops out — critical for preventing single-phasing damage on a motor. It's suitable for uninterrupted duty, meaning it's designed to carry rated current continuously without derating for time. Or screw it to a panel with an adaptor plate. It sits horizontal or vertical, so panel layout is flexible. Dimensions are 89 mm high, 45 mm wide, 78.5 mm deep — that's a 45 mm footprint per pole, standard for the TeSys Deca range. The IP20 enclosure keeps fingers out but it's not washdown-rated; keep it inside a panel. Wiring is via screw clamp terminals. Accepts up to 2 x 6 mm² solid or 2 x 4 mm² flexible with ferrules. Torque to 1.7 N·m. The push-button control on the front gives manual on/off and trip reset — no auxiliary power needed for the control circuit. Carries EN/IEC 60947-2 (circuit-breaker standard), EN/IEC 60947-4-1 (contactor/motor-starter standard), UL 60947-4-1, and CSA C22.2 No 60947-4-1. Also listed for IEC/EN 60335-2-40 (heat pump/air conditioner) and IEC/EN 60335-1 Clause 30.2 (glow-wire). Fire resistance tested to 960 °C per IEC 60695-2-11. Climatic withstand per IACS — good for marine and humid environments. Storage range is -40 to 80 °C.","metaTitle":"Schneider TeSys GV2ME01TQ Motor Circuit Breaker, 0.16 A, 100","metaDescription":"Schneider Electric TeSys Deca GV2ME01TQ motor circuit breaker. 0.16 A rated current, 100 kA breaking capacity at 400 V. UL/CSA/IEC listed. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 24","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.16 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"1.93 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.1...0.16 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.16 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/GV2ME01TQ/motor-circuit-breaker-tesys-deca-3p-0-1-to-0-16a-thermal-magnetic-screw-clamp-terminals-tq-24-units/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME01TQ/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to GV2ME01TQ in this family?","answer":"Within the TeSys GV2 family, the closest sibling is the standard GV2ME01 (without the TQ suffix). The GV2ME01TQ is a set of 24 units packaged together. The individual breaker is electrically identical — same 0.16 A rating, same breaking capacity. If you need one piece, order the GV2ME01; if you're stocking a panel shop or doing a production run, the TQ variant saves per-unit cost."},{"question":"What compliance documentation is available?","answer":"The breaker is UL listed (UL 60947-4-1), CSA certified (C22.2 No 60947-4-1), and CE marked to EN/IEC 60947-2 and 60947-4-1. It also meets IEC/EN 60335-2-40 for heat pump applications. Documentation includes the declaration of conformity and the datasheet with all test certificates. RoHS and REACH compliance is standard for Schneider's TeSys Deca line."},{"question":"What are the key ratings for panel design?","answer":"Rated current 0.16 A, magnetic trip at 1.93 A. Breaking capacity 100 kA at 400/415 V AC. Rated operational voltage 690 V AC. Power dissipation 2.5 W per pole. Mechanical durability 100,000 cycles, electrical durability 100,000 cycles at AC-3/415 V. Shock rating 30 Gn for 11 ms, vibration 5 Gn from 5 to 150 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME01TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME01TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}