{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME036","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME036","canonicalUrl":"https://aoctrl.com/schneider/GV2ME036","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME036","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 motor circuit breaker, GV2ME036, 3-pole, 0.4 A, thermal-magnetic, 100 kA breaking capacity.","salesMarkdown":"The GV2ME036 is a 3-pole motor circuit breaker from Schneider's TeSys GV2 range, rated for a line current of 0.4 A. It's a thermal-magnetic trip unit — thermal for overload protection, magnetic for short-circuit — and it's designed for motor protection duty in control panels. The 0.4 A rating places it at the low end of the family, meant for very small motors like 0.09 kW at 400 V AC. Its breaking capacity is a solid 100 kA across 230 V to 690 V AC, so it can handle high fault currents without being the weak link in your selective coordination. It can be installed horizontally or vertically. The connection pitch is 13.5 mm without spreaders, so there's enough room for ring lugs. It's IP20 rated, so finger-safe but not for wet environments.","metaTitle":"Schneider Electric GV2ME036 Motor Circuit Breaker, 0.4 A, 3-","metaDescription":"Active production motor circuit breaker from Schneider TeSys Deca range. 3-pole, 0.4 A rated current, 100 kA breaking capacity. UL/CSA/IEC certified. RFQ for sourcing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"3.09 in (78.5 mm)","Range":"TeSys Deca","Width":"1.8 in (45 mm)","Height":"3.5 in (89 mm)","Category":"US10I1122367","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with adaptor plate)","Control Type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.09 kW 400/415 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Connection pitch":"0.5 in (13.5 mm) without spreader","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Tightening torque":"15.05 lbf.in (1.7 N.m) screw clamp terminal","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"0.4 A","Operating altitude":"<= 6561.68 ft (2000 m)","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1 AC-3e IEC 60947-4-1","Electrical durability":"100000 cycles AC-3 415 V In 100000 cycles AC-3e 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks 30 Gn for 11 ms Vibrations 5 Gn, 5...150 Hz","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit lugs-ring terminals 2 0.002...0.009 in² (1...6 mm²)solid Power circuit lugs-ring terminals 2 0.002...0.009 in² (1.5...6 mm²)flexible without cable end Power circuit lugs-ring terminals 2 0.002...0.006 in² (1...4 mm²)flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529","Magnetic tripping current":"5.8 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Thermal protection adjustment range":"0.25...0.4 A IEC 60947-2","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"0.4 A IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 690 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$152.09","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/44214bca27c5d4e29a5c79e4998f0614.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME036/alternatives.json"},"ai":{"faq":[{"question":"What is GV2ME036's listed color?","answer":"The housing is dark grey."},{"question":"What is GV2ME036's depth?","answer":"Depth is 3.09 inches (78.5 mm)."},{"question":"What compliance standards does GV2ME036 meet?","answer":"It complies with EN/IEC 60947-2, IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and additional standards like IEC/EN 60335. It also passed glow-wire testing at 960 °C (IEC 60695-2-11)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME036","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME036 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}