{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME043","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME043","canonicalUrl":"https://aoctrl.com/schneider/GV2ME043","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME043","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2ME043, motor circuit breaker, 3-pole, thermal-magnetic, 0.63 A, 100 kA breaking capacity, spring terminals.","salesMarkdown":"This GV2ME043 is a 0.63 A thermal-magnetic motor circuit breaker from the TeSys Deca range. It provides motor protection with phase failure sensitivity and a magnetic trip at 9.3 A. Breaking capacity holds 100 kA across the full voltage range up to 690 V AC. IP20, ambient storage -40 to 80 °C. ## Integration Notes Spring terminals accept 1 to 6 mm² solid. Storage range -40 to 80 °C.","metaTitle":"Schneider GV2ME043 Motor Circuit Breaker, 0.63 A, 3P","metaDescription":"Schneider GV2ME043 TeSys Deca motor circuit breaker, 0.63 A, 3-pole thermal-magnetic, 100 kA breaking capacity, IP20. Active production. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"101 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.12 kW at 400/415 V AC 50/60 Hz 0.18 kW at 400/415 V AC 50/60 Hz","Product weight":"0.28 kg","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.63 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: spring terminals 2 cable(s) 1...6 mm² - solid Power circuit: spring terminals 2 cable(s) 1.5...4 mm² - flexible without cable end Power circuit: spring terminals 2 cable(s) 1...4 mm² - flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"9.3 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.4...63 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.63 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$30.48","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/870eb39e167e3567e6d3036f7612dbd2.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME043/alternatives.json"},"ai":{"faq":[{"question":"What is its depth?","answer":"78.5 mm."},{"question":"What range does it belong to?","answer":"TeSys Deca."},{"question":"What standards does it comply with?","answer":"EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC/EN 60335-2-40 Annex JJ, IEC/EN 60335-1 Clause 30.2."},{"question":"What is the breaking capacity?","answer":"100 kA Icu at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC 50/60 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME043","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME043 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}