{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME04A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME04A","canonicalUrl":"https://aoctrl.com/schneider/GV2ME04A","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME04A","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2ME04A, motor circuit breaker, 0.63 A, 3 poles, thermal-magnetic, 100 kA breaking capacity.","salesMarkdown":"GV2ME04A is a 3-pole motor circuit breaker from the TeSys Deca family, rated 0.63 A line current with a thermal-magnetic trip unit. It clips onto 35 mm DIN rail (45 mm wide, 78.5 mm deep) and is meant for motor protection in panels or machine control. The magnetic trip picks up at 9.3 A, and it’s phase-failure sensitive—so it covers both overload and single-phasing on three-phase motors. It's Category A per IEC 60947-2 and rated for motor switching per IEC 60947-4-1. The 0.63 A is fixed—set at the factory for that line current. Magnetic trip at 9.3 A protects against shorts. Power dissipation is 2.5 W per pole, so the breaker runs cool even at full load. For high-density panels, that matters more than you’d think. Suitable for isolation (per IEC 60947-1), so it doubles as a disconnect if the panel’s safety scheme allows downstream work without a separate switch. ## Sourcing reality No direct plug-and-play replacement; the GV2ME family shares the same footprint across ratings (45 mm wide, same mounting), but each ampere rating is a fixed overcurrent setting. If the BOM says 0.63 A, stick with this code.","metaTitle":"Schneider GV2ME04A TeSys Motor Circuit Breaker, 0.63 A","metaDescription":"Active-production TeSys Deca motor circuit breaker, 0.63 A thermal-magnetic, 3-pole, 100 kA breaking capacity. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Color":"Dark grey","Depth":"3.09 in (78.5 mm)","Range":"TeSys Deca","Width":"1.8 in (45 mm)","title":"GV2ME04A","Height":"4.0 in (101 mm)","Category":"US10I1122367","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with adaptor plate)","description":"Motor circuit breaker, TeSys Deca, 3P, AC-3/AC-3e, 0.4 to 0.63A, thermal magnetic, snap-in terminals, push button","Control Type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.12 kW 400/415 V AC 50/60 Hz 0.18 kW 400/415 V AC 50/60 Hz 0.37 kW 690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"0.63 A","Operating altitude":"<= 6561.68 ft (2000 m)","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1 AC-3e IEC 60947-4-1","Electrical durability":"100000 cycles AC-3 415 V In 100000 cycles AC-3e 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks 30 Gn for 11 ms Vibrations 5 Gn, 5...150 Hz","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit snap-in terminal 2 0.0008...0.004 in² (0.5...2.5 mm²)solid Power circuit snap-in terminal 2 0.0008...0.006 in² (0.5...4 mm²)flexible without cable end Power circuit snap-in terminal 2 0.0008...0.004 in² (0.5...2.5 mm²)flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529 on front face)","Magnetic tripping current":"9.3 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Thermal protection adjustment range":"0.4...63 A IEC 60947-2","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"0.63 A IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 690 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$109.65","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/55e3523f8bdc27e40898aba71e8d066a.pdf","sourceUrl":"https://www.se.com/be/en/product/GV2ME04A/motor-circuit-breaker-tesys-deca-3p-ac3-ac3e-0-4-to-0-63a-thermal-magnetic-snapin-terminals-push-button/"},"ai":{"faq":[{"question":"What compliance documentation is available?","answer":"Listed standards include EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-2-40 annex JJ and 60335-1 clause 30.2."},{"question":"What is the color and depth of the GV2ME04A?","answer":"Color is dark grey; depth is 3.09 in (78.5 mm)."},{"question":"Is there a pin-compatible alternative?","answer":"Mechanically identical to other TeSys Deca GV2ME breakers, but the 0.63 A rating is fixed. For a different current you'd order the corresponding GV2ME code, but this one is specific to 0.63 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME04A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME04A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}