{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME04AE11TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME04AE11TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2ME04AE11TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME04AE11TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2ME04AE11TQ motor circuit breaker, 3-pole, 0.63 A rated current, 100 kA breaking capacity, thermal-magnetic trip, IP20, DIN rail mount.","salesMarkdown":"The Schneider GV2ME04AE11TQ is a TeSys Deca motor circuit breaker — a 3-pole thermal-magnetic device rated at 0.63 A continuous current, designed to protect motor circuits against overload and short-circuit faults. It's part of the GV2ME family, built for motor protection duty in control panels and motor starter assemblies. The 0.63 A rating matches small motors — think fractional-horsepower pumps, fans, or conveyor drives — and the thermal-magnetic trip gives you both inverse-time overload protection and instantaneous magnetic short-circuit protection. This breaker carries a 100 kA Icu breaking capacity across the board — at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC. That's a high-fault rating for a 0.63 A device, meaning it can sit upstream of a small motor without worrying about cascading failure under a dead-short. It's certified to EN/IEC 60947-2 and 60947-4-1, plus UL 60947-4-1 and CSA C22.2 No 60947-4-1 — so it's accepted in European, North American, and Canadian panels. The utilisation category is AC-3 and AC-3e per IEC 60947-4-1, which is standard for squirrel-cage motor switching — starting, stopping, and running motors under load. Category A per IEC 60947-2 means it's not intended for selective coordination, so it's a straightforward motor-protector, not a line-side main breaker. The power terminals are screw-clamp, accepting up to 2 cables of 1–6 mm² solid or 1.5–6 mm² flexible without ferrules.","metaTitle":"Schneider GV2ME04AE11TQ Motor Circuit Breaker, 0.63 A, 100 k","metaDescription":"Schneider TeSys GV2ME04AE11TQ motor circuit breaker, 0.63 A rated current, 100 kA breaking capacity at 400 V. Thermal-magnetic trip, 3-pole, DIN rail mount. Active production, sour","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.12 kW at 400/415 V AC 50/60 Hz 0.18 kW at 400/415 V AC 50/60 Hz 0.37 kW at 690 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 20","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.63 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529 (open mounted)","Magnetic tripping current":"9.3 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","Auxiliary contact composition":"1 NO + 1 NC front","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"600 V AC 50/60 Hz conforming to UL 508 690 V AC 50/60 Hz conforming to IEC 60947-2 600 V AC 50/60 Hz conforming to CSA C22.2 No 14","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.4...63 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...40 °C in enclosure -20...60 °C open mounted","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.63 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/GV2ME04AE11TQ/motor-circuit-breakertesys-deca-frame-23p0-40-63athermal-magneticpush-buttonwith-gvae11bulk-qty/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME04AE11TQ/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"100 kA Icu at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC, per IEC 60947-2."},{"question":"What motor power does this breaker support?","answer":"It's rated for 0.12 kW at 400/415 V AC, 0.18 kW at 400/415 V AC, and 0.37 kW at 690 V AC, all at 50/60 Hz."},{"question":"Does it have phase-failure protection?","answer":"Yes, phase-failure sensitivity is built in per IEC 60947-4-1."},{"question":"What certifications does it carry?","answer":"It complies with EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC/EN 60335-2-40 Annex JJ, and IEC/EN 60335-1 Clause 30.2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME04AE11TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME04AE11TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}