{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME04AP","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME04AP","canonicalUrl":"https://aoctrl.com/schneider/GV2ME04AP","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME04AP","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 series, GV2ME04AP, motor circuit breaker, 0.63 A rated current, thermal-magnetic, 3-pole, 100 kA breaking capacity at 400 V AC.","salesMarkdown":"It uses a thermal-magnetic trip unit, so the thermal element protects against sustained overloads while the magnetic element handles short-circuit faults up to 9.3 A magnetic tripping current. The 45 mm width and 78.5 mm depth fit standard enclosure spacing — plan for that depth when laying out gland plates or busbar clearance. IP20 finger-safe terminals, so it's suited for enclosed panels where personnel access is controlled. Screw-clamp terminals accept 1 to 6 mm² solid or 1.5 to 6 mm² flexible cable, torqued to 1.7 N·m. ## Ratings that matter for motor protection At 400/415 V AC 50 Hz, this breaker covers 0.12 kW and 0.18 kW motors; at 690 V AC it covers 0.37 kW. Phase failure sensitivity is built in per IEC 60947-4-1, so it will trip if one phase drops out — prevents single-phasing damage on a motor. Electrical durability is 100,000 cycles at rated current in AC-3 duty (motor switching), matching the mechanical durability of 100,000 cycles.","metaTitle":"Schneider Electric GV2ME04AP TeSys GV2 Motor Circuit Breaker","metaDescription":"Schneider Electric GV2ME04AP TeSys GV2 motor circuit breaker, 0.63 A rated current, thermal-magnetic trip, 100 kA breaking capacity at 400 V. Active production. UL/CSA/IEC certifie","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.12 kW at 400/415 V AC 50 Hz 0.18 kW at 400/415 V AC 50 Hz 0.37 kW at 690 V AC 50 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 230/240 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"0.63 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"9.3 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"0.4...0.63 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"0.63 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50 Hz conforming to IEC 60947-2 100 % at 440 V AC 50 Hz conforming to IEC 60947-2 100 % at 500 V AC 50 Hz conforming to IEC 60947-2 100 % at 690 V AC 50 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/82f71b2ba0da4278f9f385f099a5b5e6.pdf","sourceUrl":"https://www.se.com/mk/en/product/GV2ME04AP/motor-circuit-breaker-tesys-deca-3p-0-4-to-0-63a-thermal-magnetic-screw-clamp-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME04AP/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for this part?","answer":"The GV2ME04AP is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. These cover the product safety and performance standards for motor circuit breakers in industrial control panels."},{"question":"What is the GV2ME04AP's depth?","answer":"The depth is 78.5 mm, with a width of 45 mm and height of 89 mm."},{"question":"What motor sizes does the GV2ME04AP protect at 400 V?","answer":"At 400/415 V AC 50 Hz it covers 0.12 kW and 0.18 kW motors; at 690 V AC 50 Hz it covers 0.37 kW."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME04AP","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME04AP when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}