{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME063","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME063","canonicalUrl":"https://aoctrl.com/schneider/GV2ME063","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME063","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2ME063, motor circuit breaker, 3-pole, 1.6 A, thermal-magnetic, 100 kA Icu at 400 V AC, spring terminals.","salesMarkdown":"## Integrator note Spring terminal power connections accept 1 to 6 mm² solid or 1.5 to 4 mm² flexible wire, allowing straightforward wiring in control panels. DIN-rail or panel mounting (with adaptor) fits standard enclosures; the 78.5 mm depth leaves clearance for compact cabinets. Mount on 35 mm DIN rail or screw-fix; spring terminals accept 1–6 mm² solid or 1.5–4 mm² flexible wire per pole. The dark grey 45 × 101 mm housing offers IP20 and IK04 protection, rated for uninterrupted duty per IEC 60947-4-1.","metaTitle":"Schneider GV2ME063 Motor Circuit Breaker, 1.6 A - TeSys Deca","metaDescription":"GV2ME063 motor circuit breaker, 1.6 A thermal-magnetic, 3-pole, 100 kA Icu at 400 V AC. Active production, spring terminals. Conforms to IEC/EN 60947-2 & UL 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"101 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"1.6 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: spring terminals 2 cable(s) 1...6 mm² solid Power circuit: spring terminals 2 cable(s) 1.5...4 mm² flexible without cable end Power circuit: spring terminals 2 cable(s) 1...4 mm² flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"26.2 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"1...1.6 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"1.6 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$34.29","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c4f55a28605bffd8ea5eecd67c22137e.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME063/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimension specs?","answer":"Depth 78.5 mm, width 45 mm, height 101 mm. It mounts on 35 mm DIN rail or panel with adaptor."},{"question":"What compliance standards does it meet?","answer":"It conforms to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and others."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME063","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME063 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}