{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME06A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME06A","canonicalUrl":"https://aoctrl.com/schneider/GV2ME06A","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME06A","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca motor circuit breaker, GV2ME06A, 3-pole, thermal-magnetic, 1.6 A, 100 kA breaking capacity, dark grey.","salesMarkdown":"Schneider Electric's GV2ME06A is a 3-pole thermal-magnetic motor circuit breaker from the TeSys Deca range, sized for a 1.6 A line rated current. Rated at 1.6 A, this little dark grey box handles motor starts up to 0.55 kW at 400 V or 1.1 kW at 690 V. Breaking capacity sits at 100 kA up to 690 V AC – that's a serious shortcut clearance for most industrial panels. You can often skip a separate fuse ahead of it. Rated for AC-3 and AC-3e duty, it's designed for the inrush of direct-on-line motors. Power dissipation is 2.5 W per pole – keep that in the enclosure calcs if you're stacking several. Standards cover EN/IEC 60947-2 and -4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, plus glow-wire compliance per IEC/EN 60335. You've got the paperwork for global panels.","metaTitle":"Schneider Electric GV2ME06A TeSys Deca Motor Circuit Breaker","metaDescription":"Active production 3-pole motor circuit breaker. 1.6 A thermal-magnetic trip, 100 kA breaking capacity at 690 V. IEC/UL listed. DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Color":"Dark grey","Depth":"3.09 in (78.5 mm)","Range":"TeSys Deca","Width":"1.8 in (45 mm)","title":"GV2ME06A","Height":"4.0 in (101 mm)","Category":"US10I1122367","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail clipped Panel screwed with adaptor plate)","description":"Motor circuit breaker, TeSys Deca, 3P, AC-3/AC-3e, 1 to 1.6A, thermal magnetic, snap-in terminals, push button","Control Type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.37 kW 400/415 V AC 50/60 Hz 0.55 kW 400/415 V AC 50/60 Hz 0.37 kW 500 V AC 50/60 Hz 0.55 kW 500 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 0.75 kW 690 V AC 50/60 Hz 1.1 kW 690 V AC 50/60 Hz","Fire resistance":"1760 °F (960 °C) IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz IEC 60947-2","Poles description":"3P","Climatic withstand":"IACS E10","Device Application":"Motor protection","Line Rated Current":"1.6 A","Operating altitude":"<= 6561.68 ft (2000 m)","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A IEC 60947-2 AC-3 IEC 60947-4-1 AC-3e IEC 60947-4-1","Electrical durability":"100000 cycles AC-3 415 V In 100000 cycles AC-3e 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks 30 Gn for 11 ms Vibrations 5 Gn, 5...150 Hz","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit snap-in terminal 2 0.0008...0.004 in² (0.5...2.5 mm²)solid Power circuit snap-in terminal 2 0.0008...0.006 in² (0.5...4 mm²)flexible without cable end Power circuit snap-in terminal 2 0.0008...0.004 in² (0.5...2.5 mm²)flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 IEC 60529 on front face)","Magnetic tripping current":"26.2 A","Phase failure sensitivity":"Yes IEC 60947-4-1","Product or Component Type":"Motor circuit breaker","Suitability for isolation":"Yes IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50/60 Hz IEC 60947-2","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Thermal protection adjustment range":"1...1.6 A IEC 60947-2","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-2","[Ith] conventional free air thermal current":"1.6 A IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 690 V AC 50/60 Hz IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$109.65","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8d4e9add54873f80d6f2d8089ce38d2c.pdf","sourceUrl":"https://www.se.com/us/en/product/GV2ME06A/motor-circuit-breaker-tesys-deca-3p-ac3-ac3e-1-to-1-6a-thermal-magnetic-snapin-terminals-push-button/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for the GV2ME06A?","answer":"It is listed to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1, with additional glow-wire compliance per IEC/EN 60335."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME06A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME06A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}