{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME06AE11TQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME06AE11TQ","canonicalUrl":"https://aoctrl.com/schneider/GV2ME06AE11TQ","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME06AE11TQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2 motor circuit breaker, GV2ME06AE11TQ, 1.6 A rated current, 100 kA breaking capacity, thermal-magnetic trip, 3-pole, IP20, DIN rail mount.","salesMarkdown":"Breaking capacity is 100 kA at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC — both Icu (ultimate) and Ics (service) ratings are 100 kA across that range. Dimensions are 89 mm high, 45 mm wide, 78.5 mm deep — a compact 3-pole footprint that fits standard motor-control-center buckets. Screw-clamp terminals accept up to 2 cables of 1–6 mm² solid or 1.5–6 mm² flexible without cable end, or 1–4 mm² flexible with cable end. Tightening torque is 1.7 N·m. The IP20 finger-safe enclosure suits open mounting in a cabinet; the IK04 impact rating handles incidental tool contact during panel assembly. Rated for horizontal or vertical mounting. Fire resistance tested at 960 °C per IEC 60695-2-11. These ratings confirm the breaker is suitable for standard industrial environments without derating for altitude or ambient temperature within the normal range. Compliant with EN/IEC 60947-2 (circuit-breaker standard), EN/IEC 60947-4-1 (contactor/motor-starter standard), UL 60947-4-1, and CSA C22.2 No 60947-4-1. Also meets IEC/EN 60335-2-40 Annex JJ and IEC/EN 60335-1 Clause 30.2 for household-appliance motor circuits. The UL/CSA marks mean it is accepted in North American panels without additional agency review. Phase failure sensitivity per IEC 60947-4-1 is built in — the breaker trips on loss of one phase, protecting the motor from single-phasing. ## Sourcing and BOM fit Rated for AC-3 and AC-3e utilization categories per IEC 60947-4-1 — the standard motor-switching duty. Electrical durability is 100,000 cycles at 415 V under AC-3 and AC-3e loads. Mechanical durability is also 100,000 cycles. These endurance figures match the typical life of a small motor starter in a packaging line or conveyor system. The auxiliary contact composition is 1 NO + 1 NC front-mounted, providing feedback for PLC inputs or status indication without an add-on block. Power dissipation per pole is 2.5 W, totaling 7.5 W for the three poles at rated current. This heat must be considered in enclosure thermal calculations, especially in sealed cabinets. The part is supplied as a set of 20 units, which aligns with OEM build quantities and reduces per-unit packaging waste.","metaTitle":"Schneider GV2ME06AE11TQ Motor Circuit Breaker, 1.6 A, 100 kA","metaDescription":"Schneider Electric TeSys GV2 motor circuit breaker, 1.6 A rated current, 100 kA breaking capacity at 400 V. Thermal-magnetic trip, phase failure sensitivity. Current lifecycle stag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-2-40:Annex JJ IEC/EN 60335-1:Clause 30.2","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz 0.75 kW at 690 V AC 50/60 Hz 1.1 kW at 690 V AC 50/60 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Quantity per set":"Set of 20","Breaking capacity":"100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Ics at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Ics at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Ics at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Ics at 690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"1.6 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529 (open mounted)","Magnetic tripping current":"26.2 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","Auxiliary contact composition":"1 NO + 1 NC front","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"600 V AC 50/60 Hz conforming to UL 508 690 V AC 50/60 Hz conforming to IEC 60947-2 600 V AC 50/60 Hz conforming to CSA C22.2 No 14","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"1...1.6 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...40 °C in enclosure -20...60 °C open mounted","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"1.6 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/GV2ME06AE11TQ/motor-circuit-breaker-tesys-deca-3p-1-to-1-6a-thermal-magnetic-trip-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME06AE11TQ/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the GV2ME06AE11TQ?","answer":"Rated current is 1.6 A with a thermal-magnetic trip unit. Breaking capacity is 100 kA at 230/240 V, 400/415 V, 440 V, 500 V, and 690 V AC. Magnetic tripping current is 26.2 A. It is a 3-pole motor circuit breaker with phase failure sensitivity."},{"question":"What compliance documentation does this part carry?","answer":"It is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335 series standards. The UL and CSA marks cover North American installations."},{"question":"What is the mounting and connection detail?","answer":"Mounts on 35 mm DIN rail or panel with adaptor plate. Screw-clamp terminals accept 1–6 mm² solid or 1.5–6 mm² flexible wire. Dimensions are 89 x 45 x 78.5 mm (H x W x D)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME06AE11TQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME06AE11TQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}