{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME06K1FE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME06K1FE7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME06K1FE7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME06K1FE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME DOL combination motor starter, GV2ME06K1FE7, 1...1.6 A thermal adjustment, 115 V AC 50/60 Hz control voltage, 3-pole, non-reversing.","salesMarkdown":"It integrates a 3-pole contactor, a GV2ME motor circuit breaker, and a GV2AF01 combination block into a single unit, saving panel space and wiring time compared to assembling those components separately. Rated for AC-3 utilization category, it's built for starting and stopping squirrel-cage induction motors under load. The thermal protection adjustment range of 1...1.6 A sets the overload trip point, so you match it to the motor's full-load current. The magnetic trip is fixed at 22.5 A, providing short-circuit protection coordinated with the thermal overload. ## Motor power coverage The GV2ME06K1FE7 covers motor power ratings from 0.37 kW up to 0.75 kW depending on the supply voltage. At 400/415 V it handles 0.37 kW or 0.55 kW; at 500 V it covers 0.37 kW, 0.55 kW, and 0.75 kW. That voltage-dependent power range is typical for IEC motor starters — the same thermal overload element works across a range of line voltages. As a TeSys GV2-ME family member, it shares the same footprint and combination block interface as other ratings in the series. If your motor FLA changes, swapping to a different GV2ME thermal adjustment range is straightforward without re-paneling. ## Physical integration Dimensions are 152 mm height, 45 mm width, and 87 mm depth.","metaTitle":"Schneider TeSys GV2ME06K1FE7 DOL Motor Starter, 1-1.6 A, 115","metaDescription":"TeSys GV2-ME DOL combination starter, 1...1.6 A thermal range, 115 V AC coil, 50 kA breaking capacity at 400 V. Active production. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","title":"GV2ME06K1FE7","Height":"152 mm","description":"DOL combination starter - TeSys GV2-ME - 1...1.6 A - 115 V AC","Motor power kW":"0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz 0.55 kW at 440 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 3-pole contactor 1 motor circuit breaker type GV2ME 1 combination block GV2AF01","Motor starter type":"Non reversing","Utilisation category":"AC-3","Magnetic tripping current":"22.5 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"115 V AC 50/60 Hz","Thermal Protection Adjustment Range":"1...1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a0f3c8bb13b356429b9d5711176aa835.pdf","sourceUrl":"https://www.se.com/ie/en/product/GV2ME06K1FE7/dol-combination-starter-tesys-gv2me-1-1-6-a-115-v-ac/"},"ai":{"faq":[{"question":"What are the key ratings for this motor starter?","answer":"Thermal protection adjustment range is 1...1.6 A, control voltage is 115 V AC 50/60 Hz, magnetic trip is 22.5 A, and breaking capacity is 50 kA at 400/415 V AC per IEC 60947-4-1. It covers motor power from 0.37 kW to 0.75 kW depending on line voltage."},{"question":"What does the combination block GV2AF01 do?","answer":"The GV2AF01 combination block mechanically and electrically links the contactor and circuit breaker into a single DOL starter assembly, providing coordinated operation and reducing wiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME06K1FE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME06K1FE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}