{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME06K1P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME06K1P7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME06K1P7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME06K1P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME series, GV2ME06K1P7, DOL combination motor starter, 1...1.6 A thermal protection adjustment range, 230 V AC control voltage.","salesMarkdown":"The GV2ME06K1P7 is a non-reversing DOL combination starter from the TeSys GV2-ME line, integrating a motor circuit breaker and a 3-pole contactor in one block with the GV2AF01 auxiliary contact block. The thermal protection adjustment range of 1...1.6 A is the primary selection parameter — it sets the motor full-load current window the overload relay protects against. For a 0.37 kW motor at 400/415 V AC, that window lands correctly; the same block also covers 0.55 kW at 440 V and 0.75 kW at 500 V, per the motor power table. Rated AC-3 (AC-3) utilization category, so it is designed for starting squirrel-cage induction motors — switching under load during start, not for resistive heating banks. The magnetic tripping current is set at 22.5 A, which clears short-circuit faults fast without waiting for the thermal bimetal to respond. Breaking capacity is 50 kA Iq at 400/415 V AC conforming to IEC 60947-4-1, meaning the combination starter can safely interrupt a fault current up to 50 kA at those voltages without welding contacts or rupturing the enclosure. That is a high-fault rating for this frame size — suitable for installations with substantial transformer capacity or stiff utility feeds. Coordination type is Type 1, per IEC 60947-4-1. Under a short-circuit, the contactor may need replacement after the fault, but the starter remains serviceable. For applications requiring no-contact replacement after a fault, Type 2 coordination would be specified instead. Mounts on a DIN rail. The 45 mm width (45 mm) and 152 mm height (152 mm) fit a standard modular enclosure grid; depth of 87 mm (87 mm) means it clears most shallow backboxes, but check gland-plate clearance if the panel is less than 100 mm deep. The control circuit voltage is 230 V AC 50/60 Hz (230 V AC 50/60 Hz) — the coil pulls in at that nominal; verify the control transformer secondary matches before wiring. The device composition includes the GV2AF01 auxiliary contact block as a factory-integrated element. No separate auxiliary purchase needed for basic interlocking. Product status is Active (Active). This is a current-production catalog item, not a phase-out or last-time-buy. The TeSys GV2-ME series is a mature, widely stocked line — no PCN risk in the near term.","metaTitle":"Schneider Electric GV2ME06K1P7 TeSys DOL Starter, 1-1.6 A, 2","metaDescription":"Active TeSys GV2-ME DOL combination motor starter, 1-1.6 A thermal range, AC-3 duty, 50 kA breaking capacity at 400 V. Sourced to order per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","title":"GV2ME06K1P7","Height":"152 mm","description":"DOL combination starter - TeSys GV2-ME - 1...1.6 A - 230 V AC","Motor power kW":"0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz 0.55 kW at 440 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 combination block GV2AF01 1 motor circuit breaker type GV2ME 1 3-pole contactor","Motor starter type":"Non reversing","Utilisation category":"AC-3","Magnetic tripping current":"22.5 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"230 V AC 50/60 Hz","Thermal Protection Adjustment Range":"1...1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4048351bd2f938d2746fa3b3eb606a8a.pdf","sourceUrl":"https://www.se.com/sg/en/product/GV2ME06K1P7/dol-combination-starter-tesys-gv2me-1-1-6-a-230-v-ac/"},"ai":{"faq":[{"question":"What is the thermal protection adjustment range and what motor does it cover?","answer":"The thermal protection adjustment range is 1...1.6 A. At 400/415 V AC, that covers a 0.37 kW motor; at 440 V it covers 0.55 kW; at 500 V it covers 0.55 kW or 0.75 kW depending on the exact line voltage."},{"question":"What breaking capacity does it have at 400 V?","answer":"50 kA Iq at 400/415 V AC, conforming to IEC 60947-4-1. That is the rated short-circuit making and breaking capacity for the combination starter."},{"question":"What control voltage does the coil require?","answer":"230 V AC at 50/60 Hz. The coil is designed for that nominal voltage; verify the control transformer secondary matches before energizing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME06K1P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME06K1P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}