{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME06K2Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME06K2Q7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME06K2Q7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME06K2Q7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME DOL reversing combination motor starter, GV2ME06K2Q7, thermal protection 1...1.6 A, 380...400 V AC control voltage.","salesMarkdown":"The Schneider Electric GV2ME06K2Q7 is a DOL reversing combination motor starter from the TeSys GV2-ME range. It integrates a motor circuit breaker, a 3-pole reversing contactor, and a combination block (GV2AF01) into one pre-wired unit — a single order code that replaces three separate components on the BOM. Thermal protection adjusts from 1 to 1.6 A, so it's sized for small three-phase motors — think fractional-horsepower conveyors, fan coils, or pump drives. The magnetic trip is fixed at 22.5 A, which clears short-circuit faults fast without nuisance tripping on inrush. Rated for AC-3 utilisation category, meaning it's built for starting and stopping squirrel-cage induction motors under load — not just resistive switching. The 50 kA breaking capacity at 400/415 V AC (IEC 60947-4-1) means it safely interrupts fault currents up to that level without upstream fuses needing to clear first, as long as Type 1 coordination is acceptable. The 45 mm wide footprint clips onto standard DIN rail. At 152 mm tall and 87 mm deep, it leaves room above for a control transformer or PLC output card. The reversing contactor is mechanically interlocked inside the assembly, so there's no risk of phase-to-phase short when the direction changes. Motor power output varies by supply voltage: 0.37 kW at 400 V, 0.55 kW at 440 V, and up to 0.75 kW at 500 V. It is a current-production TeSys GV2-ME variant.","metaTitle":"Schneider GV2ME06K2Q7 TeSys reversing starter, 1-1.6 A","metaDescription":"Schneider Electric TeSys GV2ME06K2Q7 DOL reversing combination motor starter. Thermal protection 1...1.6 A, 50 kA breaking capacity at 400 V AC. Active production, sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","Height":"152 mm","Motor power kW":"0.37 kW at 400/415 V AC 50/60 Hz 0.55 kW at 400/415 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz 0.55 kW at 440 V AC 50/60 Hz 0.37 kW at 500 V AC 50/60 Hz 0.55 kW at 500 V AC 50/60 Hz 0.75 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 combination block GV2AF01 1 3-pole reversing contactor 1 motor circuit breaker type GV2ME","Motor starter type":"Reversing","Utilisation category":"AC-3","Magnetic tripping current":"22.5 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"380/400 V AC 50/60 Hz","Thermal Protection Adjustment Range":"1...1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/uk/en/product/GV2ME06K2Q7/dol-reversing-combination-starter-tesys-gv2me-1-1-6-a-380-400v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME06K2Q7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the GV2ME06K2Q7?","answer":"Thermal protection range 1...1.6 A, magnetic trip fixed at 22.5 A, breaking capacity 50 kA at 400/415 V AC (IEC 60947-4-1), control voltage 380/400 V AC, and motor power up to 0.75 kW at 500 V AC."},{"question":"What does the 50 kA breaking capacity mean for installation?","answer":"It means the starter can interrupt a short-circuit fault of up to 50 kA at 400 V without needing upstream fuses to clear first, as long as Type 1 coordination is acceptable — the starter may need replacement after a fault, but the downstream motor and wiring are protected."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME06K2Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME06K2Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}