{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME07AP","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME07AP","canonicalUrl":"https://aoctrl.com/schneider/GV2ME07AP","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME07AP","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca GV2ME07AP motor circuit breaker, 3-pole, 2.5 A rated current, thermal-magnetic trip, 100 kA breaking capacity at 400 V AC.","salesMarkdown":"It's a 3-pole thermal-magnetic device with a rated current of 2.5 A, sized to protect a 0.75 kW motor at 400/415 V AC 50 Hz. It's phase-failure sensitive per IEC 60947-4-1, so it will trip if one phase drops out — a common cause of motor burnouts on lightly loaded lines. In a panel with a transformer-fed supply capable of 65 kA fault current, this breaker still has headroom. Utilisation category AC-3 (IEC 60947-4-1) means it's rated for starting and stopping squirrel-cage motors — the standard duty for motor circuit breakers. AC-3e is the energy-efficient motor variant, same switching duty but tested with motors that draw higher inrush. Electrical durability is 100,000 cycles at 415 V at rated current for both AC-3 and AC-3e — that's a solid service life for a panel-mounted breaker. Dimensions are 89 mm high, 45 mm wide, 78.5 mm deep — a standard 45 mm module width that fits alongside contactors in a motor control centre. IP20 finger-safe protection on the front; IK04 impact resistance means it can take a knock from a dropped tool during panel servicing. Operating altitude is limited to 2000 m — above that, derate for air density. Certified to EN/IEC 60947-2 (circuit-breaker standard) and EN/IEC 60947-4-1 (contactor/motor-starter standard), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1 for North American installations. Fire resistance rated at 960 °C per IEC 60695-2-11. Climatic withstand conforms to IACS for marine and offshore environments.","metaTitle":"Schneider GV2ME07AP TeSys Motor Circuit Breaker, 2.5 A, 100","metaDescription":"Schneider Electric TeSys GV2ME07AP motor circuit breaker. 2.5 A rated current, 100 kA breaking capacity at 400 V. Thermal-magnetic protection, phase failure sensitive. Active produ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"TeSys Deca","Width":"45 mm","title":"GV2ME07AP","Colour":"Dark grey","Height":"89 mm","Standards":"EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Rated duty":"Uninterrupted conforming to IEC 60947-4-1","Fixing mode":"35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)","description":"Motor circuit breaker, TeSys Deca, 3P, 1.6 to 2.5A, thermal magnetic, screw clamp terminals","Control type":"Push-button","Network type":"AC","Product name":"TeSys GV2","Motor power kW":"0.75 kW at 400/415 V AC 50 Hz 1.1 kW at 500 V AC 50 Hz 1.5 kW at 690 V AC 50 Hz","Fire resistance":"960 °C conforming to IEC 60695-2-11","lifecycle_stage":"current","Breaking capacity":"100 kA Icu at 230/240 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50 Hz conforming to IEC 60947-2","Device short name":"GV2ME","Mounting position":"Horizontal Vertical","Network frequency":"50/60 Hz conforming to IEC 60947-2","Poles description":"3P","Tightening torque":"1.7 N.m - on screw clamp terminal","Climatic withstand":"conforming to IACS E10","Device application":"Motor protection","Operating altitude":"<= 2000 m","[In] rated current":"2.5 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1","Electrical durability":"100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In","Mechanical durability":"100000 cycles","Mechanical robustness":"Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5...150 Hz","Connections - terminals":"Power circuit: screw clamp terminal 2 cable(s) 1...6 mm²solid Power circuit: screw clamp terminal 2 cable(s) 1.5...6 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 1...4 mm²flexible with cable end","IK degree of protection":"IK04","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping current":"39 A","Phase failure sensitivity":"Yes conforming to IEC 60947-4-1","Product or component type":"Motor circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-1","Power dissipation per pole":"2.5 W","[Ui] rated insulation voltage":"690 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"690 V AC 50 Hz conforming to IEC 60947-2","Ambient air temperature for storage":"-40...80 °C","Thermal protection adjustment range":"1.6...2.5 A conforming to IEC 60947-2","Ambient air temperature for operation":"-20...60 °C","[Uimp] rated impulse withstand voltage":"6 kV conforming to IEC 60947-2","[Ith] conventional free air thermal current":"2.5 A conforming to IEC 60947-2","[Ics] rated service short-circuit breaking capacity":"100 % at 230/240 V AC 50 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50 Hz conforming to IEC 60947-2 100 % at 440 V AC 50 Hz conforming to IEC 60947-2 100 % at 500 V AC 50 Hz conforming to IEC 60947-2 75 % at 690 V AC 50 Hz conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1f7a8a6243d8f8e517896772a831bfdc.pdf","sourceUrl":"https://www.se.com/mk/en/product/GV2ME07AP/motor-circuit-breaker-tesys-deca-3p-1-6-to-2-5a-thermal-magnetic-screw-clamp-terminals/"},"ai":{"faq":[{"question":"What are the key ratings for the GV2ME07AP?","answer":"Rated current is 2.5 A, magnetic trip at 39 A, breaking capacity 100 kA Icu at 400/415 V AC. Motor power rating is 0.75 kW at 400/415 V AC 50 Hz. Rated operational voltage is 690 V AC. It is a 3-pole thermal-magnetic motor circuit breaker with phase-failure sensitivity."},{"question":"What compliance documentation does Schneider provide for the GV2ME07AP?","answer":"The GV2ME07AP carries certifications to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. It also meets fire resistance at 960 °C per IEC 60695-2-11 and climatic withstand per IACS for marine environments."},{"question":"What is the physical size of the GV2ME07AP?","answer":"Dimensions are 89 mm high, 45 mm wide, and 78.5 mm deep. It mounts on 35 mm symmetrical DIN rail or panel-mounts with an adaptor plate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME07AP","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME07AP when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}