{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"GV2ME07K1Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"GV2ME07K1Q7","canonicalUrl":"https://aoctrl.com/schneider/GV2ME07K1Q7","factsUrl":"https://aoctrl.com/api/mcp/products/GV2ME07K1Q7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys GV2-ME, DOL combination motor starter, GV2ME07K1Q7, 1.6...2.5 A thermal adjustment, 380...400 V AC control, 3-pole, non-reversing.","salesMarkdown":"The Schneider Electric TeSys GV2ME07K1Q7 is a DOL (direct-on-line) combination motor starter, integrating a GV2ME motor circuit breaker, a GV2AF01 combination block, and a 3-pole contactor into one unit. The thermal protection adjustment range is 1.6...2.5 A, so it protects motors drawing full-load current in that band — set the dial to the motor nameplate FLA. The magnetic tripping current is fixed at 33.5 A, which clears short-circuit faults fast without nuisance trips on normal starting inrush. Breaking capacity is 50 kA Iq at 400/415 V AC, conforming to IEC 60947-4-1. That 50 kA figure is the prospective short-circuit current the starter can safely interrupt under Type 1 coordination — after a fault the contactor may need replacement, but the breaker clears without rupturing. For a panel with high fault current (say, near a large transformer), this rating avoids cascading damage upstream. Motor power is 0.75 kW at 400/415 V AC, 0.75 kW at 440 V, and 1.1 kW at 500 V — match the motor voltage to the line voltage; the kW rating changes with voltage. ## Where this class of part is used This DOL combination starter is used in motor control panels for fixed-speed pumps, fans, compressors, and conveyors where reversing is not required. The integrated breaker and contactor save DIN-rail space and reduce wiring compared to separate components. The 45 mm width and 152 mm height fit standard enclosure layouts.","metaTitle":"Schneider TeSys GV2ME07K1Q7 DOL Starter, 1.6-2.5 A, Obsolete","metaDescription":"Schneider Electric TeSys GV2ME07K1Q7 DOL combination motor starter, 1.6-2.5 A thermal range, 50 kA breaking capacity at 400 V. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"87 mm","Range":"TeSys","Width":"45 mm","Height":"152 mm","Motor power kW":"0.75 kW at 400/415 V AC 50/60 Hz 0.75 kW at 440 V AC 50/60 Hz 1.1 kW at 440 V AC 50/60 Hz 1.1 kW at 500 V AC 50/60 Hz","lifecycle_stage":"current","Breaking capacity":"50 kA Iq at 400/415 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 440 V AC 50/60 Hz conforming to IEC 60947-4-1 50 kA Iq at 500 V AC 50/60 Hz conforming to IEC 60947-4-1","Coordination type":"Type 1","Device short name":"GV2ME","Poles description":"3P","Device composition":"1 motor circuit breaker type GV2ME 1 combination block GV2AF01 1 3-pole contactor","Motor starter type":"Non reversing","Utilisation category":"AC-3","Magnetic tripping current":"33.5 A","Product or component type":"Motor starter","[Uc] control circuit voltage":"380/400 V AC 50/60 Hz","Thermal Protection Adjustment Range":"1.6...2.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d568f734af97e99abf5f5b39254de14f.pdf","sourceUrl":"https://www.se.com/uk/en/product/GV2ME07K1Q7/dol-combination-starter-tesys-gv2me-1-6-2-5-a-380-400v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/GV2ME07K1Q7/alternatives.json"},"ai":{"faq":[{"question":"What is the thermal protection adjustment range of the GV2ME07K1Q7?","answer":"The thermal protection adjustment range is 1.6...2.5 A. Set the dial to the motor nameplate full-load current within that band."},{"question":"What is the breaking capacity of the GV2ME07K1Q7?","answer":"The breaking capacity is 50 kA Iq at 400/415 V AC, 440 V AC, and 500 V AC, conforming to IEC 60947-4-1 under Type 1 coordination."},{"question":"What is the control circuit voltage for the GV2ME07K1Q7?","answer":"The control circuit voltage is 380/400 V AC 50/60 Hz. The coil is rated for that range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/GV2ME07K1Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/GV2ME07K1Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}